– 23 –
XMIT TO CONFIRM
PRESS ✱ TO SKIP
Confirm
[∗] to continue
• If “Yes” was entered at the SET TO CONFIRM? prompt
previously (see first prompt following entry into the ∗58
Expert Programming Mode), the display on the left will
appear. Confirm serial and loop numbers by activating the
wireless key.
IMPORTANT:
When confirmed, the key is not active for arming/disarming until
it is assigned to a user number (using the assigning attributes
command, attribute “4”). See System Operation section for
procedure.
Entd A022-4063
Rcvd A022-4064
Not Confirmed
[∗] to continue
If the serial number transmitted does not match the serial
number entered, a display similar to the one shown will appear.
If the loop number does not match, it will also be displayed.
If so, activate the button on the wireless key once again. If a
match is not obtained (i.e., summary display does not appear),
press the [#] key and then enter the correct serial number.
If the serial number transmitted matches the serial number
entered, the keypad will beep 3 times and will return you to the
Zone Number prompt to enter the starting zone for the next
wireless key.
Or you can return to *58 Menu mode by pressing 00 at the Zone
Number prompt.
Wireless Key Predefined Default Templates
5834-013-V0
SERIAL #1
LOOP 4
SERIAL #1
LOOP 1
SERIAL #2
LOOP 1
SERIAL #2
LOOP 3
SERIAL #1
LOOP 3
SERIAL #
LOOP 4
SERIAL #1
LOOP 2
SERIAL #2
LOOP 2
5834-4 Wireless Key
Transmitter
LOOP 4
5804-001-V4
LOOP 3
LOOP 1
LOOP 2
5804 Wireless Key
Transmitter
LOOP 3
LOOP 1
LOOP 2
LOOP 4
RED/YELLOW
LED
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
GREEN/YELLOW
LED
ENROLL AS "BR"
5804BD-007-V1
5804BD 2-Way Wireless Key
Transmitter
NOTE: Some transmitters are not intended for use in UL installations.
For Button-Type Devices
For Button-Type Devices
TEMPLATE 1 Loop Function Zone Type TEMPLATE 4 Loop Function Zone Type
1 No Response 23 1 No Response 23
2 Disarm 22 2 No Response 23
3 Arm Away 21 3 Arm Away 21
4 No Response 23 4 Disarm 22
TEMPLATE 2 Loop Function Zone Type TEMPLATE 5 Loop Function Zone Type
1 No Response 23 1 No Response 23
2 Disarm 22 2 Arm Stay 20
3 Arm Away 21 3 Arm Away 21
4 Arm Stay 20 4 Disarm 22
TEMPLATE 3 Loop Function Zone Type TEMPLATE 6 Loop Function Zone Type
1 24-hour audible 7 1 24-hour audible 7
2 Disarm 22 2 Arm Stay 20
3 Arm Away 21 3 Arm Away 21
4 Arm Stay 20 4 Disarm 22
Deactivating & Removing a Wireless Key from the System
Deactivate a wireless key by deleting the associated user code:
Delete the User Code: Master code + [8] + 2-digit user no. + [#] [0]
Remove a wireless key from the system by deleting one of the wireless key zones using Zone Programming mode:
1. Press *56 while in Program mode then enter a zone number assigned to the wireless key.
2. Scroll through each prompt by pressing [∗] until the Input S/N prompt appears.
3. Enter 0 for the loop number and press [∗].
4. Exit program mode.