ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Programming Guide

Pagina 2 - APPLIANCES

– 10 – ∗∗∗∗65 Open Report Code See above for entries. [0,0,0] System Reporting Note above *59. Part. 1 Part. 2 Comm

Pagina 3

– 11 – OUTPUT AND SYSTEM SETUP (✱77 – ✱93) ∗∗∗∗77 Daylight Saving Time Start/End Month 0 = Disabled 1-9 = Jan.-Sept. (1 = Jan, 2 = Feb, etc) #+10

Pagina 4 - PROGRAMMING MODE COMMANDS

– 12 – ∗∗∗∗89 Event Log Full Report Code See box above field *59 for report code entries. | [00] If an Event Logging selection is made i

Pagina 5

– 13 – ∗∗∗∗93 Reports In Armed Period Per Zone (Swinger Suppression) Restrict Report Pairs: 0 = Unlimited Reports 1 = 1 report pair per zone per

Pagina 6

– 14 – ∗∗∗∗160 Pager 1 Phone No. Enter up to 20 digits. 0–9 #+11 = '✱' #+12 = '#' #+13 = 2-second pause | | |

Pagina 7

– 15 – ∗∗∗∗172 Pager Delay Option For Alarms 0 = none 1 = 1 minute 2 = 2 minutes 3 = 3 minutes [3] This field determines the delay of alarm

Pagina 8 - Time Delay Disable

– 16 – ∗∗∗∗182 Configurable Zone Type 90 (0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).

Pagina 9

– 17 – ∗∗∗∗190 Keypad 2 Device Address 17 Entry 1: Partition/ Enable VISTA-20P: Enter partition in which the keypad is located where: For Stan

Pagina 10 - Part. 1 Part. 2 Common

– 18 – CONFIGURABLE ZONE TYPES WORKSHEET Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fie

Pagina 11

– 19 – ∗∗∗∗56 ZONE PROGRAMMING MENU MODE (press *56 while in Program mode) The Zone Programming Worksheet is on page 44. Zones and Partitions Eac

Pagina 12 - Options RIS Enable

– 2 – RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper

Pagina 13 - Restrict V20PSIA/V15PSIA

– 20 – 10 Report Code 1st 01 2nd 00 10 Report Code (RC) First Digit: 1-9, 10 for 0, 11 for B, 12 for C, 13 for D, 14 for E, 15 for F 00 to

Pagina 14 - [0,0,0]

– 21 – 10 INPUT S/N L A022-4064 ? Loop Number Change [∗] to continue NOTE: If the [C] key is used to copy the previously enrolle

Pagina 15

– 22 – Zn ZT P RC IN: L 10 00 1 10 RF 1 Zone Programming ZT = see Zone Type chart shown in *56 Menu Mode “Zone Type” prompt P = p

Pagina 16 - [1, 1, 0, 0]

– 23 – XMIT TO CONFIRM PRESS ✱ TO SKIP Confirm [∗] to continue • If “Yes” was entered at the SET TO CONFIRM? prompt previously (see first promp

Pagina 17 - Partition/ Sound

– 24 – ∗∗∗∗57 FUNCTION KEY PROGRAMMING MENU MODE (press ∗∗∗∗57 while in Data Programming mode) The Function Key Worksheet is on page 45. The system

Pagina 18 - OPEN SHORTEDINTACT

– 25 – OUTPUT DEVICE PROGRAMMING GENERAL INFORMATION (*79/*80 Menu Mode) Output Devices: The VISTA-20P system supports up to 16 relays and/or Powe

Pagina 19

– 26 – XX OUTPUT TYPE DELETE 0 Output Type 0 = delete 1 = relay on 4204/4229 2 = Powerline Carrier Device [∗] to continue Select whether thi

Pagina 20

– 27 – 80 Menu Mode Output Funct. # (00 = Quit) 01 Output Function No. (VISTA-20P: 01-48 (VISTA-15P: 01-24) [∗] to continue; 00 to quit Enter t

Pagina 21 - TO CONFIRM

– 28 – “C” 01 Enter Zn No. 12 Zone Number Press [✱] to continue. (prompt appears if zone number was selected) Enter the desired zone number

Pagina 22 - ENTER START ZONE

– 29 – 01 Delete Zone? 0 = No 1 = Yes 0 Deleting a Zone 0 = don’t delete zones 1 = go to next prompt to delete zones [∗] to continue To save th

Pagina 23 - 5834-013-V0

– 3 – TABLE OF CONTENTS PROGRAMMING MODE COMMANDS ...

Pagina 24

– 30 – EXAMPLE: (a) ✱ ZN 01 B ACK (b) ✱ ZN 01 BACK (c) ✱ ZN 01 BACK D OOR (d) ✱ ZN 01 BACK DOOR Descriptor Example EXAMP

Pagina 25 - 0 = NO 1 = YES 0

– 31 – ALPHA VOCABULARY LIST (For Entering Zone Descriptors) 000 (Word Space) – A – • 001 AIR • 002 ALARM ∗∗∗∗ 004 ALLEY 005 AMBUSH • 006

Pagina 26

– 32 – SETTING SCHEDULES (Installer Code + [#] + [6] [4]) The system provides schedules, which can be used to automatically control 11 types of sys

Pagina 27 - AVS/GSMV4G session end §

– 33 – REPEAT OPTION 0-4 X Repeat Option 0 = do not repeat 1 = repeat weekly 2 = repeat biweekly (every other week) 3 = repeat every third week 4

Pagina 28 - ∗81 ZONE LIST MENU MODE

– 34 – ∗∗∗∗29 COMMUNICATION DEVICE MENU MODE (Pass-Through Programming) This mode is for programming an IP, GSM, or IP/GSM Communicator Module using a

Pagina 29

– 35 – Registering the Communication Device with AlarmNet The communication device must be registered with AlarmNet before internet communication (vi

Pagina 30

– 36 – ZONE TYPE DEFINITIONS Zone types define the way in which the system responds to faults in each zone. Type 00 Zone Not Used Program a zone wi

Pagina 31

– 37 – REPORT CODE FORMATS The following table describes the communication formats. FORMAT TYPE DESCRIPTION 3+1 and 4+1 Standard Formats Ex. SSS(S)

Pagina 32 - HH MMAM 0010000

– 38 – SYSTEM SECURITY CODES The systems provides one Installer code, one System Master code, plus a set of other user codes intended for other users

Pagina 33 - 0=NO 1=YES X

– 39 – KEYPAD FUNCTIONS The following is a brief list of system commands. For detailed information concerning system functions, refer to the User&apo

Pagina 34 - 6160-7720P-001-V0

– 4 – PROGRAMMING MODE COMMANDS Compatibility: This document applies to systems with microprocessor version 9.1 or higher. TO ENTER PROGRAMMING MODE

Pagina 35 - System Requirements

– 40 – VARIOUS SYSTEM TROUBLE DISPLAYS Alpha Display Fixed Disp. Meaning ALARM CANCELED CA Will appear if an exit or interior zone contained a f

Pagina 36 - ZONE TYPE DEFINITIONS

– 41 – UL NOTICES 1. Entry Delay No. 1 and No. 2 (fields ∗35, ∗36) cannot be greater than 30 seconds for UL Residential Burglar Alarm installations

Pagina 37 - REPORT CODE FORMATS

– 42 – FCC STATEMENTS FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 The user shall not make any changes or modifications to the equipment unless au

Pagina 38 - SYSTEM SECURITY CODES

– 43 – LIMITATIONS STATEMENT WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced design security system, it does not offe

Pagina 39 - COMPATIBLE DEVICES

– 44 – WORKSHEET for ∗∗∗∗56 ZONE PROGRAMMING (VISTA-15P supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part.

Pagina 40

– 45 – WORKSHEET for ∗∗∗∗57 FUNCTION KEY PROGRAMMING Option Function A P1 P2 com B P1 P2 comC P1 P2 comD P1 P2 comComments 01 Paging

Pagina 41 - SIA QUICK REFERENCE GUIDE

– 46 – WORKSHEET for ∗∗∗∗80 OUTPUT FUNCTION PROGRAMMING Fill in the required data on the worksheet below and follow the programming procedure in t

Pagina 42 - FCC STATEMENTS

– 47 – WORKSHEET for SCHEDULES (installer code + [#] + [6] [4]; master code can only access schedules 01-16 for VISTA-20P, 01-04 for VISTA-15P, and

Pagina 43 - CONTACTING TECHNICAL SUPPORT

5800 SERIES TRANSMITTER INPUT LOOP IDENTIFICATION All of the transmitters illustrated have one or more unique factory assigned input (loop) ID number

Pagina 44 - ∗56 ZONE PROGRAMMING

– 5 – DATA FIELD PROGRAMMING FORM Entries apply to the ADEMCO VISTA-15P/VISTA-15PSIA and ADEMCO VISTA-20P/VISTA-20PSIA controls, except entries sho

Pagina 45

– 6 – ∗∗∗∗28 Access Code For Phone Module 00 = disable 1st digit: enter 1–9 2nd digit: enter # + 11 for "∗", or # + 12 for "#&qu

Pagina 46 - WORKSHEET

– 7 – ∗∗∗∗38 Confirmation Of Arming Ding 0 = no 1 = yes (wired keypads and RF) 2 = yes, RF only (except 5827, 5827BD) [0,0]

Pagina 47 - TABLE OF DEVICE ADDRESSES

– 8 – ∗∗∗∗49 Split/Dual Reporting 0 = Standard/backup reporting only (all to primary) 1-5 = see table at right [0] Backup Reporting: All

Pagina 48 - ÊK5305-1PRV8wŠ

– 9 – ∗∗∗∗55 Dynamic Signaling Priority / AAV Path Select (continued) For AAV Path Select: • If using the UVS system or AVS system with non-ECP