Installation Instructions
4-2
FIELD
TITLE and DATA ENTRIES EXPLANATION
*27
Powerline Carrier Device (X-10)
House ID
0 = A 6 = G # + 11 = L
1 = B 7 = H # + 12 = M
2 = C 8 = I # + 13 = N
3 = D 9 = J # + 14 = O
4 = E # + 10 = K # + 15 = P
5 = F
Powerline Carrier devices require a House ID, identified in this field.
Program Powerline Carrier devices in interactive modes 79, *80 and
*81.
Not intended for fire or UL installations.
*28
Language Select
0 = English 2 = Italian
1 = Spanish 3 = Portuguese
Select the desired keypad display language.
UL installations must be 0 (English)
*29
ECP Contact ID Output for ACM
0 = not used
1 = use Contact ID output on ECP
If selected, all messages programmed to go to the primary telephone
line receiver will also be sent (in Contact ID format) to the connected
Alternative Communication Media (ACM), such as a 7845i
Internet/Intranet Communicator or AI4164RS/AI4164ETH Eureka
Network Interface, or 7845C/7835C cellular radio (in selected
countries). The data line is supervised as well as certain functions in
a long range radio. If communication is lost or a trouble develops, an
attempt will be made to send a message via both ACM and telephone
to the central station.
Program the ACM for device address 3.
*30
Make Partition 3 a Common Area
Partition
0 = no (must be 0 if system uses zone type
82 - Blockschloss)
1 = yes, make partition 3 a common area
partition
If selected, partition 3 functions as a common area partition, rather
than as an independent partition.
Zone Sounds & Timing
FIELD
TITLE and DATA ENTRIES EXPLANATION
*31
Single Alarm Sounding Per Zone/
Dialer/Bell Disable if Arm Stay
0 -7 = see table of entries at right
Select whether a zone going into alarm should sound more than once
per armed period and whether Bell and/or Dialer should be disabled if
armed STAY.
UL installations must be 0 (no limit).
Entry Single Alarm
Sound
Disable Bell if
Armed STAY
Disable Dialer if
Armed STAY
0
No UL: must be “0”
No No
1 Yes No No
2 No Yes No
3 Yes Yes No
4 No No Yes
5 Yes No Yes
6 No Yes Yes
7 Yes Yes Yes
*32
Fire Alarm Sounder Timeout
0 = yes; fire sounder timeout after time
programmed in field 33
1 = no fire sounder timeout; continue
sounding until manually turned off
Select whether fire alarm sounding expires after sounder timeout or
remains until manually turned off.
UL fire alarm installations: must be 1.
*33
Bell (Siren) Timeout
0 = No timeout 4 = 4 min
1 = 1 min 5 = 8 min
2 = 2 min 6 = 16 min
3 = 3 min
This field determines whether the external sounder will shut off after
time allotted, or continue until manually turned off.
UL installations: For residential fire alarm installation, must be set
for a minimum of 4 min (option 4); for UL Commercial Burglary
installations, must be minimum 16 min (option 6).
*34
Exit Delay
00 - 96 = 0 - 96 seconds
97 = 120 seconds
The system waits the time entered before arming entry/exit zones. If
the entry/exit door is left open after this time expires, an alarm will
occur or the zone will be auto-bypassed, depending on the selection in
field *88. Common area zones use same delay as partition 1.
UL installations: For UL Commercial Burglar Alarm (Grade AA) and
UL Residential Burglar Alarm installations with line security, total
exit time must not exceed 60 seconds. For UL Burglar Alarm
installations without line security (Grade A), total exit time must not
exceed 120 seconds.