ADEMCO VISTA-48D Especificaciones Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
Installation Instructions
3-2
Keypads
Keypads are identified by predefined addresses (starting at address 16) as follows:
Address Keypad Program Field
16 keypad 1 always enabled for partition 1, all sounds enabled. NOTE: First keypad is address 16.
17 keypad 2 data field *190
18 keypad 3 data field *191
19 keypad 4 data field *192
20 keypad 5 data field *193
21 keypad 6 data field *194
22 keypad 7 data field *195
23 keypad 8 data field *196
To enable keypads:
1. Set desired address at keypad (refer to keypad’s instructions for setting the address).
2. Use data field program mode to enable keypad addresses, assign a partition, enable sound options
in fields *190-*196 as shown in the table above.
3. If desired, use data field *198 to turn on the display of the partition number.
4. Set the following keypad-related data fields as required by the installation:
*21 Quick Arm Enable 180 Zone Bypass Limit
*23 Forced Bypass 186 Display Options
25 Arming Prevention Override 188 Keypad Sabotage Options
*84 Auto STAY Arm
197 Exit Time Display Interval
88 Exit Options NOTE: Do not use this option if Telecommand is installed to permit
remote end-user control of the system.
Wireless Receiver Transmitters, and Wireless Keys (keyfobs)
Receiver: Set the receiver’s address to “00” using its DIP switches, then set the following options:
*22 RF Jam Option
††
*24 RF House ID Code (if using DIP switch equipped wireless keypads) for each partition
25 Arming Prevention Override
*67 Transmitter Low Battery Report Code
††
*75 Transmitter Low Battery Restore Report Code
††
173 RF Reporting Options
178 RF Supervision/RF Jam Options
Use *56 Menu mode to program wireless zones 9-48 and wireless button zones 49-64.
Transmitters: Use *56 or *58 Zone Programming Menu modes to program zone information and
enroll transmitters (zones 9-48, buttons 49-64).
Wireless Keys: Use Wireless Key Programming Templates section of the *58 Zone Programming
Menu mode to program zone information and enroll each button of the wireless keys used. Once a
wireless key is enrolled, it must be assigned to a user before it becomes active. See Adding/Deleting
Security Codes section for procedure.
Pager Programming
The system can send various reports to up to 3 pagers.
To program pager reporting, do the following:
1. Enter the appropriate information in the following data fields:
*160, *163, *166 Pager Phone Numbers (for pagers 1-3 respectively)
*161, *164, *167 Pager Prefix Characters (for pagers 1-3 respectively)
*162, *165, *168 Pager Reporting Options by Partition
(for pagers 1-3 respectively)
2. Enable Pager Delay, if desired, in field *169 (delays alarm reporting for ALL pagers).
3. Enable appropriate user open/close pager reports using the user attribute command
(master code + [8] + user no. + [#] [5] + [1]). Users that perform actions in their assigned partition
will, if enabled, attempt to report to all pagers enabled for open/close reporting in that partition.
†† These fields must be enabled for Residential
Fire, UL Residential Burglar Alarm, and UL
Commercial Burglar Alarm installations.