VISTA-100 Installation Instructions
24-2
The following table describes each format in greater detail:
3+1 and 4+1 Standard
Formats
Comprised of a 3- or 4-digit subscriber number and a single-digit
report code (e.g., Alarm, Trouble, Restore, Open, Close, etc.).
3+1 and 4+1 Expanded
Formats
Comprised of a 3- or 4-digit subscriber number and a 2-digit report
code. The first digit is displayed on the first line, followed by a
second line where the first digit is repeated 3 or 4 times and is
followed by the second digit. This is the “expanded” digit.
4+2 Format Comprised of a 4-digit subscriber number and 2-digit report code.
ADEMCO Contact ID
Reporting Format
Comprised of a 4-digit subscriber number, 1-digit event qualifier
("new" or "restore"), 3-digit event code, 2-digit partition number,
and 3-digit zone number, user number, or system status number.
ADEMCO High Speed Comprised of 13 digits: a 4-digit account number, eight channels of
zone information (1-8 or duress plus 9-15), and one status channel,
which identifies the type of event being reported in the eight zone
locations.
Report 3+1/4+1 3+1/4+1 4+2
Standard Expanded Low Speed or
Express
Alarm SSS(S) A SSS(S) A SSSS AZ
AAA(A) Z
Trouble SSS(S) T SSS(S) T SSSS Tt
TTT(T) t
Bypass SSS(S) B SSS(S) B SSSS Bb
BBB(B) b
AC Loss SSS(S) E SSS(S) E SSSS EA
C
EEE(E) A
C
Low Batt SSS(S) L SSS(S) L SSSS LL
B
LLL(L) L
B
Open SSS(S) O SSS(S) O SSSS OU
OOO(O) U
Close SSS(S) C SSS(S) C SSSS CU
CCC(C) U
Test SSS(S) G SSS(S) G SSSS Gg
GGG(G)g
Restore SSS(S) R SSS(S) R SSSS RZ
Alarm RRR(R) Z
AC Restore SSS(S) R
A
SSS(S) R
A
SSSSR
A
A
c
R
A
R
A
R
A
(R
A
)A
c
LoBat Res. SSS(S) R
L
SSS(S) R
L
SSSS R
L
L
B
R
L
R
L
R
L
(R
L
)L
B
Trouble Res. SSS(S) R
T
SSS(S) R
T
SSSS R
T
t
R
T
R
T
R
T
(R
T
)t
Bypass Res. SSS(S) R
B
SSS(S) R
B
SSSS R
B
b
R
B
R
B
R
B
(R
B
)b
Where:
SSS or SSSS = Subscriber ID C = Close Code (1st digit)
A = Alarm Code (1st digit) U = User Number (1st & 2nd digits)
Z = Typically Zone Number (2nd digit) Gg = Test Code (1st & 2nd digits)
Tt = Trouble Code (1st & 2nd digits) R = Restore Code-Alarm (1st & 2nd digits)
Bb = Bypass Code (1st & 2nd digits) R
T
t = Restore Code-Trbl (1st & 2nd digits)
EA
C =
AC Loss Code (1st & 2nd digits) R
B
b = Restore Code-Byps (1st & 2nd digits)
LL
B =
Low Battery Code (1st & 2nd digits) R
A
A
C
= Restore Code-AC (1st & 2nd digits)
O = Open Code (1st Digit) R
L
L
B =
Restore Code-Bat (1st & 2nd digits)
*Zone numbers for: [T] + [#], or [B] = 99; [3] + [#], or [C] = 96; – [1] + [
T