VISTA-100 Installation Instructions
1-xiv
Certain system options are selectable for each partition, such as Entry/Exit Delay and
subscriber account number
User Codes
Accommodates 128 user codes, all of which can operate any or all partitions. The following
characteristics must be assigned to each user code:
Authority level (Master, Manager, or several other Operator levels)
Opening/closing central station reporting option
Which partitions the code can operate
Global arming capability (the ability to arm all partitions to which the code has access in
one command)
Use of an RF (button) to arm and disarm the system (RF key must first be programmed
into the system)
Peripheral Devices
Supports up to 31 addressable devices, which can be any combination of keypads
(6139/6139R), RF receivers (4281/5881), relay modules (4204/4204CF), and 4285/4286 VIP
Module. Peripheral devices have the following characteristics:
Each device is set to an individual address (physically) according to the device's
instructions
Each device is enabled in the system using the Device Programming Mode (see “Device
Programming” in Section 22: #93 Menu Mode Programming)
At least one 2-line alpha keypad (6139/6139R) must be connected to the system for programming
(if using keypad programming) and must remain connected to the system in order to allow the
primary user to program additional user codes into the system at a later time.
Keypad Panic Keys
Accommodates three keypad panic keys: 1 +
(A),
+ [#] (B), and 3 + [#] (C).
Designated as zones 995 (1 +
), 996 (3 + [#]), and 999 (
+ [#])
Activated by wired and wireless keypads
Activated and reported separately by partition, distinguished by subscriber account
number (or partition number if Contact ID reporting is used)
Keypad Macros
Accommodates one keypad macro command per partition (each macro is a series of keypad
commands), which can be assigned to the "D" key on each partition's keypads. This means,
for example, that by pressing the "D" key, the system can be programmed to log onto
another partition, bypass zones 2 and 3, and arm that partition in the AWAY mode (See
Section 28: Keypad Functions). Characteristics of keypad macros are:
Assignable to the "D" key by partition
Can each be 16 characters (keystrokes) in length
Bell Outputs
Provides two style-Y supervised bell outputs on the control panel itself. A 4204CF Relay
Module can supply two additional style Y supervised bell outputs.