VISTA-100 Installation Instructions
23-20
#83 User Scheduling Menu Mode
The system provides up to 20 "timers" that allow the end user to control output devices
(4204 relay). These timers are comparable to the individual appliance timers that can be
purchased at a department store. The output devices themselves are programmed into the
system by the installer during #93 Menu Mode–Relay Programming. To control a device,
the end user only needs to know the output device number and its alpha descriptor.
The installer can set certain relays to be "restricted" during # 93 Menu Mode-Relay
Programming. These relays cannot be controlled by the end user. This prevents end users
from controlling doors, pumps, etc.
To access this mode, the user enters [Security Code] + [#] + 83.
Output Timer # ?
01-20, 00=Quit 01
Enter the number (01-20) to be programmed for the output
timer. Press
to accept the entry.
Enter 00 to exit and return to normal mode.
06 07:00P 11:45P
PORCH LITE 04
If the timer number you entered has already been
programmed, a summary screen appears. In the example at
left:
06 = Timer #
04 = Output Device # affected by this timer
PORCH LITE = Descriptor for Output Device # 4
07:00PM = Start Time
11:45PM = Stop Time
Press
to continue.
06 ENTER OUTPUT#
PORCH LITE 04
Enter the desired output number (01-16).
As the number is entered, the descriptor changes to indicate
which output device is being affected.
You can enter
00
as the output number to delete the timer. The system will display an output
descriptor of "None."
06 ON TIME?
07:00 PM
Enter the ON time in 00:01 - 11:59 format. When the display
shows the desired time, press
to move to the AM/PM field.
Press any number key to toggle the indicator between AM and
PM. Enter 00:00 to skip.
06 OFF TIME?
11:45 PM
Enter the OFF time in 00:01 - 11:59 format. When the display
shows the desired time, press
to move to the AM/PM field.
Press any number key to toggle the indicator between AM and
PM. Enter 00:00 to skip.
06 DAYS? MTWTFSS
HIT 0-7 x x
To select the days to be activated, enter 1-7 (Monday = 1). An
"X" will appear under that day. Entering a day's number again
will deactivate that day. Press 0 to toggle all days on or off.
The outputs will be in effect for the days that have the letter
“X” under them. As the week progresses, the selected days are
reset to the inactive state, unless the permanent option is
selected at the next screen prompt.
When you are finished, press
to continue.
06 Permanent?
0 = NO,1 = YES 0
The Permanent option puts this schedule in effect on a
continuous basis. Enter 1 to turn the Permanent option on.