Section 21 - Data Field Descriptions
21-9
1*23 CROSS ZONING PAIR TWO
||
||
Enter the second pair of zones that must both be faulted within a 5-minute period to
cause an alarm. Enter 000,000 to disable this feature, if you do not want to define a
second pair of cross-zones.
You must set this field to 000,000 for UL Burglary Installations.
1*24 CROSS ZONING PAIR THREE
||
||
Enter the third pair of zones that must both be faulted within a 5-minute period to
cause an alarm. Enter 000,000 to disable this feature, if you do not want a third pair of
cross-zones.
You must set this field to 000,000 for UL Burglary Installations.
1*25 CROSS ZONING PAIR FOUR
||
||
Enter the fourth pair of zones that must both be faulted within a 5-minute period to
cause an alarm. Enter 000,000 to disable this feature, if you do not want a fourth pair
of cross-zones.
You must set this field to 000,000 for UL Burglary Installations.
1*28 RF TX LOW BATTERY SOUND
[0]
Enter 0 if you want an audible beep and display in the event of an RF transmitter low-
battery condition only when the system is in the disarmed state. Enter 1 if you want an
audible beep and display when the system is in either an armed or a disarmed state.
You must set this field to 1 for UL installations.
1*29 RF TX LOW BATTERY REPORT ENABLE
[0]
Enter 1 if you want a Trouble message for an RF transmitter low-battery condition to
be sent to the central station. Enter 0 if you do not want a report on a transmitter low-
battery condition. Note that a Trouble message will be sent for a transmitter
supervision failure independent of this selection.
You must set this field to 1 for UL installations.
1*30 RF RCVR SUPERVISION CHECK-IN INTERVAL
[06]
|
Enter the check-in monitoring interval. The system will multiply the number you
enter by 2 hours to calculate the interval. Enter a number from 02 (4 hours) to 15 (30
hours). Failure of a receiver to receive any RF signal within the time you entered will
result in activation of the response type programmed for zone 990 for the first receiver
and zone 988 for the second receiver, and their related communication reports. Enter
00 to disable receiver supervision.
For UL installations, the maximum interval is 4 hours (enter 2).
1*31 RF TRANSMITTER CHECK-IN INTERVAL
[12]
|
Enter the check-in monitoring interval. The system will multiply the number you
enter by 2 hours to calculate the interval. Enter a number from 02 (4 hours) to 15 (30
hours). Failure of an individual transmitter to send a supervision signal within the
time you entered will result in a trouble response and related communication report.
Enter 00 to disable transmitter supervision.
For UL installations, the maximum interval is 4 hours (enter 2).
1*32 RECEIVER TYPE
[0]
Enter 1 if you are using 4281 Series receivers. Enter 2 if you are using 5881 Series
receivers. Important: The 4281 Microprocessor must have part number N5334Vx,
where x is any number.