Section 22 - #93 Menu Mode Programming
22-5
Device Programming
Use this menu to program keypads, receivers, and relay modules.
From Data Field Programming Mode, press #93 to display "ZONE PROG?". Press 0
repeatedly to until "DEVICE PROG?" is displayed.
DEVICE PROG?
1=YES 0=NO
Press 1 to enter Device Programming Mode.
DEVICE ADDRESS
01-31, 00=QUIT
The device address identifies the device to the control. Enter
the 2-digit device address number to match the device's
physical address setting (01-30). Press
✴
to accept the
entry.
Note: You must use Device Address 04 for the 4285/4286 Voice
Module, if you are using one. If not, you can use Address 04
for another device type.
DEVICE TYPE
Select the type of addressable device as follows:
0 = device not used
1 = alpha keypad (6139/6139R)
3 = RF receiver (4281/5881)
4 = output relay module (4204)
5 = voice (VIP) module (4285/4286)
Press
✴
to accept the entry.
SUPERVISED CF?
If you selected device type 4 (output relay module) in the last
step, this prompt will appear. Enter 1 if the unit is a 4204CF.
If it is not, enter 0. If you enter 1, you will be able to program
only Relay 1 (Output A) and Relay 3 (Output B) for functions
on each module. This module is usually used to add two
additional supervised bell outputs to the system.
Press
✴
to continue.
CONSOLE PART.
If you selected device type 1 (alpha keypad), this prompt will
appear. Enter the addressable device's default partition
number (01 to the maximum number of partitions that you
programmed for the system in field 2*00). This is the primary
partition for which you intend to use the device. Enter 9 to
make this keypad a "Master" keypad for the system. Press
✴
to accept the entry.
RF EXPANDER
HOUSE ID XX
If you selected device type 3 (RF receiver), this prompt will
appear. Enter the 2-digit House ID (00-31). This is required
for 5700 Series systems only, or for using a wireless keypad
(5827/5827BD) with a 5800 Series system.
MODULE PART.
If you selected device type 5 (VIP Module), this prompt will
appear. Enter the partition number (1-8) in which the module
is located. Press
✴
to accept the entry.