21-1
SECTION 21
Data Field Descriptions
••••••••••••••••••••••••••••••••••••••••••••••••
The following is a description of all data fields provided by the VISTA-100. If you have
followed earlier instructions during the installation of the various devices, many of these
fields will already have been programmed. The field default values are shown in brackets.
For more information about actual programming procedures, see Section 18: The Mechanics
of Programming.
*00 INSTALLER CODE
|||
The Installer Code is a 4-digit code reserved for installation company use. This is the
only code that can be used to enter the Program Mode from the keypad. This code
cannot be used to disarm the system if it was not used to arm the system. You cannot
use this code to re-enter Programming Mode if you exited by using the
*
98 command.
*08 TEMPORAL SIREN PULSE
[0]
If you program either bell for pulsing (program field 3
*
15), the Temporal Siren Pulse
field will determine the rhythm and rate of pulsing as follows: If you enter 1 to enable,
the pulse rate will be three dings followed by a pause, then repeated. If you enter 0, the
pulse rate will be 1 sec. on, 1 sec. off.
*09 ENTRY DELAY #1
(partition-specific) [02]
|
Entry Delay defines the delay time during which a user can re-enter the premises
through a door (that was programmed for entry delay) and disarm the system without
sounding an alarm. The number you enter is multiplied by 15 seconds to calculate the
delay time. The valid range is from 0 (no delay) to 15 (for a delay of 225 seconds). For
zones assigned to Zone Type 01.
*10 EXIT DELAY #1
(partition-specific) [03]
|
Exit Delay defines the delay period that allows users to leave the premises through a
door (that was programmed for entry/exit delay) after arming the system, without
setting off the alarm. The system multiplies the number you enter by 15 seconds to
calculate the delay time. The valid range is from 0 (no delay) to 15 (for a delay of 225
seconds). For zones assigned to Zone Type 01.
*11 ENTRY DELAY #2
(partition-specific) [06]
|
Use Entry Delay #2 to set the delay time for a secondary door requiring a longer delay
than that assigned to Entry Delay #1.
This delay may not exceed 45 seconds for UL Commercial Burglary installations.
*12 EXIT DELAY #2
(partition-specific) [08]
|
Use Exit Delay #2 to set the delay time for a secondary door requiring a longer delay
than that assigned to Exit Delay #1.
This delay may not exceed 60 seconds for UL Commercial Burglary installations.