ADEMCO Security System VISTA-10SE Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
– 8 –
Programming a Data Field
1. Press [
] plus Field No. (for example,
21), then make the desired entry.
2. When you have completely programmed a data field, the keypad will “beep”
three times and then automatically display the next data field in sequence.
To go to a different field, press [
] plus the desired field No.
3. If the number of digits that you need to enter in a data field is less than the
maximum digits available (for example, the phone number field), enter the
desired data, then press
and the next data field number to be programmed.
4. If you try to enter a non-existent field, an Alpha keypad will display NOT
USED and EE (Entry Error). Simply key [
] again plus a valid field number.
Reviewing a Data Field/Erasing an Entry in a Data Field
Press [#] plus Field No. Data will be displayed for that field number. No
changes will be accepted in this mode.
To delete an entry in a field, press [
] plus Field No. + [
]. (Applies only to
fields
40 –
42, and
94.)
Interactive Menu Mode Programming (
56,
80,
81,
82 and
83)
Typical prompt displayed
during interactive menu
mode programming
Enter Zn Num.
(00 = Quit) 01
Zone Number
Press [
] plus menu mode No. (for example,
56). The Alpha keypad will
display the first of a series of prompts requesting entries.
A detailed procedure (with displays of prompts) is provided in those sections in
the Installation Instructions where programming in the menu mode is to be
performed.
Menu Mode Used To Program
56 Zone Programming Zone characteristics, report codes, alpha descrip-
tors and serial numbers for 5800 transmitters
80 Relay Programming 4204 Relay modules
81 Zone List Programming Zone Lists for 4204 relay activation
82 Alpha Programming Zone alpha descriptors
83 Sequential Mode 5800 series transmitter serial numbers
Loading Factory Defaults (
97)
To load the Ademco factory defaults, enter the programming mode, press
97,
then exit the programming mode.
Do not press
97 if you program new values in place of the factory defaults—
the new values will be changed back to the factory default values!
96 resets the Subscriber Account number and CSID in preparation for an
initial download.
Programming System Setup Fields
The following program fields MUST be programmed (as required) before
doing any programming.
22 RF SYSTEM (Default is 0).
Enter “1” if 5700 RF system type is being used; enter “2” if a 5800 RF
system type is being used; enter “0” if no RF is being used.
25 OUTPUT RELAY MODULE (Default is 0).
Enter “3” if a 4204 relay is being used, or “0” if a relay is not being used.
Exiting the Programming Mode
98 EXITS PROGRAMMING MODE and prevents re-entry by Installer
Code + [8] + [0]. To enter the programming mode if
98 was used to exit,
you must first power the system down. Then power up again, and press
[
] and [#] both at once, within 50 seconds of powering up.
99 EXITS PROGRAMMING MODE and allows re-entry by:
Installer Code + [8] + [0] or by:
Pressing [
] and [#] at the same time, within 50 seconds of powering up
the system.
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 23 24

Comentarios a estos manuales

Sin comentarios