– 4 –
✱46 REPORT FORMAT
[0]
Also see field
✱27.
[0 = 3+1, 4+1 ADEMCO L/S STANDARD]
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
✱47 SPLIT/DUAL REPORTING
[0] 0 = Disable (Backup report only)
TO PRIMARY PHONE No. TO SECONDARY PHONE No.
1 = Alarms, Restore, Cancel Other Reports
2 = All Reports except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All Reports
4 = All Reports except Open/Close, Test All Reports
5 = All Reports (
Dual Reporting)
All Reports
**
A 10-digit code is sent to the pager consisting of
a 4-digit Subscriber #, a 3-digit Event code, & a
3-digit User or Zone #. See VISTA-10SE
Installation Instructions for an explanation of the
10-digit code.
TO PRIMARY PHONE No. TO PAGING No.* (SECONDARY)
6 = All reports except Open/Close ** Alarms, Open/Close, Troubles
7 = All reports ** Alarms, Troubles
8 = All reports ** Alarms, Open/Close, Troubles
9 = All reports except Open/Close ** Alarms, Open/Close for Users 5 –25
†
,
Troubles
* Can only be used if Primary reporting is Ademco Contact ID.
†
See field ✱ 47 in the DATA FIELD DESCRIPTIONS section.
✱48 15 SEC DIALER DELAY (BURG)
†
[0]
0 = no; 1 = yes
✱49 PERIODIC TEST MESSAGE
†
[0]
0 = none; 1 = 24 hrs; 2 = wkly; 3 = monthly. Enter Test Code in field ✱64.
✱50 SESCOA/RADIONICS SELECT
†
[0]
0 = Radionics (0-9, B-F reporting); 1 = SESCOA (0-9 only reporting)
Select 0 for all other formats.
✱51 CONFIRMATION OF ARMING DING
†
[0]
0 = no; 1 = yes; 2 = yes, but with RF arming only.
✱52 ZONE 3 RESPONSE TO OPEN
†
[0]
0 = 400 ms nominal; 1 = 10 ms nominal
†
Entry of a number other than one specified will give unpredictable results.
✱56 ZONE ASSIGNMENT/ALARM REPORT CODES (See explanation on next page)
ZONE ZONE ZONE ALARM RPT CODE INPUT RF INPUT
DESCRIPTION No. TYPE (Hex) TYPE LOOP
(Zn) (ZT) (RC) (In) (L)
Wired Zone 1 0 1 [01] HW —
Wired Zone 2 0 2 [04] HW —
Wired Zone 3 0 3 [03] HW —
Wired Zone 4 0 4 [03] HW —
Wired Zone 5 0 5 [09] HW —
Wired Zone 6 0 6 [07] HW —
Keypad Panic (✱ & #, or B) 0 7 [06] ——
Keypad Duress 0 8 — — ——
Tamper 0 9 0 5 ——
Keypad Panic (1 & ✱, or A) 9 5 [00] ——
Keypad Panic (3 & #, or C) 9 6 [00] ——
RF EXPANSION ZONES: With 4281L, up to 4 RF expansion zones available; 4281M or 4281H, up to 8; ENTER FOR
5881L, up to 8; 5881M or 5881H, up to 16.
↓
5800 ONLY
↓
ZONE ZONE ZONE ALARM RPT CODE INPUT RF INPUT
DESCRIPTION No. TYPE (Hex) TYPE LOOP
(Zn) (ZT) (RC) (in) (L)
1st RF Expansion Zone
2nd
3rd
4th