46 REPORT FORMAT
[0]
Also see field
27.
[0 = 3+1, 4+1 ADEMCO L/S STANDARD]
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
47 SPLIT/DUAL REPORTING
[0] 0 = Disable (Backup report only)
TO PRIMARY PHONE No. TO SECONDARY PHONE No.
1 = Alarms, Restore, Cancel Other Reports
2 = All Reports except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All Reports
4 = All Reports except Open/Close, Test All Reports
5 = All Reports (
Dual Reporting)
All Reports
**
A 10-digit code is sent to the pager consisting of
a 4-digit Subscriber #, a 3-digit Event code, & a
3-digit User or Zone #. See VISTA-10SE
Installation Instructions for an explanation of the
10-digit code.
TO PRIMARY PHONE No. TO PAGING No.* (SECONDARY)
6 = All reports except Open/Close ** Alarms, Open/Close, Troubles
7 = All reports ** Alarms, Troubles
8 = All reports ** Alarms, Open/Close, Troubles
9 = All reports except Open/Close ** Alarms, Open/Close for Users 5 –25
,
Troubles
* Can only be used if Primary reporting is Ademco Contact ID.
See field 47 in the DATA FIELD DESCRIPTIONS section.
48 15 SEC DIALER DELAY (BURG)
[0]
0 = no; 1 = yes
49 PERIODIC TEST MESSAGE
[0]
0 = none; 1 = 24 hrs; 2 = wkly; 3 = monthly. Enter Test Code in field 64.
50 SESCOA/RADIONICS SELECT
[0]
0 = Radionics (0-9, B-F reporting); 1 = SESCOA (0-9 only reporting)
Select 0 for all other formats.
51 CONFIRMATION OF ARMING DING
[0]
0 = no; 1 = yes; 2 = yes, but with RF arming only.
52 ZONE 3 RESPONSE TO OPEN
[0]
0 = 400 ms nominal; 1 = 10 ms nominal
Entry of a number other than one specified will give unpredictable results.
56 ZONE ASSIGNMENT/ALARM REPORT CODES (See explanation on next page)
ZONE ZONE ZONE ALARM RPT CODE INPUT RF INPUT
DESCRIPTION No. TYPE (Hex) TYPE LOOP
(Zn) (ZT) (RC) (In) (L)
Wired Zone 1 0 1 [01] HW
Wired Zone 2 0 2 [04] HW
Wired Zone 3 0 3 [03] HW
Wired Zone 4 0 4 [03] HW
Wired Zone 5 0 5 [09] HW
Wired Zone 6 0 6 [07] HW
Keypad Panic (& #, or B) 0 7 [06] ——
Keypad Duress 0 8 ——
Tamper 0 9 0 5 ——
Keypad Panic (1 & , or A) 9 5 [00] ——
Keypad Panic (3 & #, or C) 9 6 [00] ——
RF EXPANSION ZONES: With 4281L, up to 4 RF expansion zones available; 4281M or 4281H, up to 8; ENTER FOR
5881L, up to 8; 5881M or 5881H, up to 16.
5800 ONLY
ZONE ZONE ZONE ALARM RPT CODE INPUT RF INPUT
DESCRIPTION No. TYPE (Hex) TYPE LOOP
(Zn) (ZT) (RC) (in) (L)
1st RF Expansion Zone
2nd
3rd
4th