Example 1. Pager displays: 1234–911–004
This indicates that Subscriber No. 1234’s system is reporting an
Alarm (911), due to zone 4 being faulted (004).
Example 2. Pager displays: 1234–001–005
This indicates that Subscriber No. 1234’s system is reporting an
opening (001) by User 5 (005).
Note that no restore reports are sent to the pager.
Important:
AAV should not be used when Paging or Alarm Reports are being sent to a
Secondary number. If this is done, the call to the Secondary number by the
communicator after the alarm report will prevent the AAV from taking control
of the telephone line, and the AAV “Listen in” session cannot then take place.
48 15-SECOND DIALER DELAY (BURGLARY) Default is 0.
Single-digit entry. If selected, will provide 15-second delay of burglary
alarm report to the central station. Allows time for subscriber to avoid a
false alarm transmission.
0 for no delay, or 1 for 15-second delay.
49 PERIODIC TEST REPORT (1-Digit Entry) Default is 0.
Select the desired test report interval.
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days.
Test Report code entered in field
64 is sent; reports with Subscriber No.
U
L
For UL installations, 24 hours (1) must be selected
50 SESCOA/RADIONICS SELECT (1-Digit Entry) Default is 0.
0 = Radionics (0–9, B–F reporting)
1 = SESCOA (0–9 only reporting)
Select 0 for all other formats.
51 CONFIRMATION OF ARMING DING (1-Digit Entry) Default is 0.
Enter 1 to enable 1/2 second external alarm sounding “ding” when
closing report goes in, or at the end of exit delay. Enter 2 for alarm
sounding ding with RF arming (this will work with either a button RF
unit or a 5827.
0 disables the “ding”.
52 ZONE 3 RESPONSE TIME TO OPEN (1-Digit Entry) Default is 0.
0 = 400ms nominal; 1 = 10ms nominal.
56 ZONE ASSIGNMENT/ALARM REPORT CODES
This is an interactive menu mode that is used to program zone
numbers, zone types, alarm and report codes, and to identify the
type of loop input device.
This mode can also be used for entering 5800 series transmitter serial
numbers (serial numbers can also be entered using the Sequential Mode
in
83, but only after all other zone programming has been completed in
56).
Alpha descriptors can also be entered for zones in
56 (alternatively,
Alpha descriptors can be entered in menu mode
82).
Refer to the BASIC HARDWIRED ZONES 1–6 section in the Installation
Instructions for detailed hardwired zone programming, and the
WIRELESS (RF) ZONE EXPANSION (5700 & 5800 RF SYSTEMS) section for
detailed wireless zone expansion programming.
Refer also to the zone assignment table for
56 in the programming form
in this manual.