– 5 –
RF EXPANSION ZONES: With 4281L, up to 4 RF expansion zones available; 4281M or 4281H, up to 8; ENTER FOR
5881L, up to 8; 5881M or 5881H, up to 16.
↓
5800 ONLY
↓
ZONE ZONE ZONE ALARM RPT CODE INPUT RF INPUT
DESCRIPTION No. TYPE (Hex) DEVICE LOOP
(Zn) (ZT) (RC) (in) (L)
5th
6th
7th
8th
9th
10th
11th
12th
13th
14th
15th
16th
EXPLANATION OF ZONE ASSIGNMENT TABLE
Zn = ZONE NUMBER Zone Nos. are from 01 to 63, 95, 96. Some are pre-assigned.
With Field ✱22 set for RF (5700 or 5800), use Zone Nos. 10-63 .
ZT = ZONE TYPE 00 = Zone Not Used
01 = Entry/Exit
02 =
Do not use
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
20 = Arm–Stay *
21 = Arm–Away*
22 = Disarm*
23 = No Alarm Response
* 20, 21, & 22 used for 5800 RF systems only.
RC = ALARM REPORT CODE Two Hex Digits. For each Hex Digit, enter: 00–09 for 0–9, 10 for A, 11 for B, 12 for C, 13 for D, 14 for E, 15 for F.
If "00" is entered in the first pair of boxes, there will be no report for that zone.
For contact ID reporting, this is an enabling code only. Make any hex digit entry (other than "00") in the first
pair of boxes. The second pair of boxes will be ignored.
In = RF INPUT DEVICE
HW: Hard Wire Enter 3 for RF: Supervised RF (this is the default)
Enter 4 for UR: Unsupervised RF
Enter 5 for BR: Button Type RF
L = RF INPUT LOOP Used with 5800 RF Input Devices. Record transmitter input number.
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT
CODES (✱ 60 – ✱ 75):
With a 3+1 or 4+1 Standard Format: Enter a code in the
first
box: 1-9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B,
"#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F.
A "0" (
not
"#+10") in the
first
box will disable a report.
A "0" (
not
"#+10") in the
second
box will result in automatic
advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in
both
boxes
(1st and 2nd digits) for 1-9, 0, or B-F, as described above.
A "0" (
not
"#+10") in the
second
box will eliminate the ex-
panded message for that report.
A "0" (
not
"#+10") in
both
boxes will disable the report.
With Ademco Contact ID Reporting: Enter any digit (other than
"0") in the
first
box, to enable zone to report (entries in the
second
boxes will be ignored).
A "0" (
not
"#+10") in the
first
box will disable the report.
Examples:
For Code 3 (Single Digit), enter: 3 0
For Code 32 (Two Digits), enter: 3 2
For Code B2 (Hexadecimal) enter: #+11 2
SYSTEM STATUS REPORT CODES (✱60 – ✱68)
✱60 TROUBLE REPORT CODE
✱61 BYPASS REPORT CODE
✱62 AC LOSS REPORT CODE
✱63 LOW BATTERY REPORT CODE
✱64 TEST REPORT CODE
✱65 OPEN/EXIT ALARM REPORT CODE /
2nd digit of OPEN REPORT is automatically sent as the
user number if expanded or 4+2 reporting is selected.
2nd digit of EXIT ALARM REPORT is automatically sent as
the 2nd digit of the zone alarm report code programmed in
✱56, if expanded or 4+2 reporting is selected.
✱66 AWAY/STAY CLOSE REPORT CODE /
2nd digit of any CLOSE REPORT is automatically sent as the user
number, if expanded or 4+2 reporting is selected.
✱67 RF XMTR LOW BAT REPORT CODE
✱68 CANCEL REPORT CODE
RESTORE REPORT CODES (✱70 – ✱75)
✱70 ALARM RESTORE REPORT CODE
2nd digit is automatically sent as the 2nd digit of the
zone alarm report code programmed in ✱ 56, if
expanded or 4+2 reporting is selected.
✱71 TROUBLE RESTORE REPORT CODE
✱72 BYPASS RESTORE REPORT CODE
✱73 AC RESTORE REPORT CODE
✱74 LOW BAT RESTORE REPORT CODE
✱75 RF XMTR LO BAT RST REPORT CODE
Comentarios a estos manuales