– 18 –
✱
66 AWAY/STAY CLOSE REPORT CODE (2-Digit Entry)
(See box on previous page.)
To enable, enter a code (or 0 to disable) in either or both boxes.
For expanded or 4+2 reporting, 2nd digit for each = User # .
✱
67 RF XMTR. LOW BATTERY REPORT CODE (2-Digit Entry)
(See box on previous page).
✱
68 CANCEL REPORT CODE (2-Digit Entry)
(See box on previous page.)
RESTORE
REPORT CODES
(
✱
70 –
✱
75)
✱
70 ALARM RESTORE REPORT CODE
(See box on previous page). For expanded or 4+2 reporting, a 2nd digit is
automatically sent, and is the same as the 2nd digit of the zone alarm
report code programmed in field
✱
56.
✱
71 TROUBLE RESTORE REPORT CODE (2-Digit Entry)
(See box on previous page). This is sent when a trouble in a zone is
restored.
✱
72 BYPASS RESTORE REPORT CODE (2-Digit Entry)
(See box on previous page) . This is sent when a zone that has been
bypassed is un-bypassed.
✱
73 AC RESTORE REPORT CODE (2-Digit Entry)
(See box on previous page) . Reports with Subscriber No.
✱
74 LOW BAT RESTORE REPORT CODE (2-Digit Entry)
(See box on previous page). Reports with Subscriber No.
✱
75 RF XMTR. LOW BATTERY RESTORE CODE (2-Digit Entry)
(See box on previous page). This is sent when a transmitter that
previously sent in a low battery message has sent a message indicating
it no longer has a low battery condition.
✱
80 OUTPUT RELAYS
This is an interactive menu mode that is applicable only if 4204 relays
are to be used (“3” in field
✱
25). See the RELAY OUTPUTS section in
the Installation Instructions for a detailed programming procedure.
Also refer to the OUTPUT RELAY table for field
✱
80 in the
Programming Form in this manual.
✱
81 ZONE LISTS FOR OUTPUT DEVICES
This is an interactive menu mode that is applicable only if field
✱
25 is
programmed for a 4204 relay. Refer to the RELAY OUTPUTS section in
the Installation Instructions for a detailed programming procedure.
Also refer to the ZONE LISTS FOR OUTPUT RELAYS table for
✱
81 in
the Programming Form in this manual.
✱
82 CUSTOM ALPHA EDITING
See the ALPHA DESCRIPTION PROGRAMMING section in the
Installation Instructions for procedure.
✱
83 SEQUENTIAL MODE
May be used for enrolling transmitters in a 5800 RF system after all
other zone information has been programmed in
✱
56. See the
Installation Instructions for a detailed programming procedure.
✱
91 OPTION SELECTION (1-Digit Entry) Default is 0.
Enter “4” if an Audio Alarm Verification (AAV) unit is connected in the
system (1–3 not used); enter “0” if an AAV unit is not being used.
For UL installations, the AAV option must be disabled (0).
Important: AAV should not be used when Paging or Alarm Reports are
being sent to a Secondary number. If this is done, the call to the
Secondary number by the communicator after the alarm report will
prevent the AAV from taking control of the telephone line, and the AAV
“Listen in” session cannot take place.