– 19 –
92 NUMBER OF REPORTS IN ARMED PERIOD Default is 0.
(1-Digit Entry). This option can be used to limit the number of messages
(alarm & alarm restore reports) sent to the central station in an armed
period. “0” limits reports to a total of 10; “1” allows an unlimited
number of reports.
U
L
“1” must be selected for UL installations
DOWNLOAD
INFORMATION
(
94,
95)
94 DOWNLOAD PHONE NUMBER
Enter up to 12 digits; 0–9, # +11 for “
”, # + 12 for “#”, # + 13 for a
pause. Do not fill unused spaces. End field by entering
. To clear
entries from field, press
94
.
95 RING DETECTION COUNT FOR DOWNLOADING Default is 0.
Enter number of rings before control picks up phone line (or 0 or 15).
Refer to the chart below and program this field accordingly.
Phone Answering
Module Machine Downloading Field
95
Yes No No Set for value other than “0” (1–14). This will
enable the control panel to answer the phone
call. Otherwise, it will not be possible to
access the Phone Module
Yes Yes No Set for a value higher than the number of
rings for which the answering machine is
set. Example: if machine is set for 4 rings,
use a value of 5 or higher. This is recom-
mended so that the Phone Module can still
be accessed if the answering machine is
turned off and does not answer the phone
call.
Yes No Yes Set for value other than “0” (1–14).
Yes Yes Yes Enter “15” to bypass answering machine.
No No No Enter “0”.
No Yes No Enter “0”.
No No Yes Enter 1–14.
No Yes Yes Enter 15. See Important Note below.
Important Note: If “15” is entered in field
95 to bypass an answering machine, and a 4285 Phone
Module is included in the installation, you should note the following:
When calling in from an off-premises phone (to receive a status report or execute a command), the
user should make the initial call, allow 1 to 3 rings only, and hang up. Then call in again – the Phone
Module will now seize the line, and 2 long tones will be heard, followed by the usual voice prompt for
the 2-digit phone access code. If this procedure is not followed, Phone Module operation will not be
possible.
96 INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. No.
FOR DOWNLOADING (No data entry required; press
96)
97 SET ALL PROGRAM FIELDS TO DEFAULT VALUES
(No data entry required; pressing
97 automatically loads all Ademco
defaults). Do not use if previously programmed with other values.
TO EXIT
PROGRAMMING MODE
(
98 or
99)
98 EXITS PROGRAMMING MODE and prevents re-entry by :
INSTALLER Code + 8 + 0 .
To enter the programming mode if
98 was used to exit, you must
first power the system down. Then power up again, and depress [
]
and [#] both at once, within 50 seconds of powering up.
99 EXITS PROGRAMMING MODE and allows re-entry by:
INSTALLER Code + 8 + 0 or by method described in paragraph
above (power down, power up and depress [
] and [#] both at once,
within 50 seconds of powering up.).