–15–
SUPPLEMENTARY
POWER SUPPLY
+
–
CONTROL
TERMINAL STRIP
AUX AUX. DATA DATA
– + IN OUT
4567
IMPORTANT:
MAKE THESE
CONNECTIONS
DIRECTLY TO
SCREW
TERMINALS AS
SHOWN.
TO KEYPAD RED WIRE
TO KEYPAD BLK WIRE
TO KEYPAD YEL WIRE
TO KEYPAD GRN WIRE
TO KEYPAD BLK WIRE
TO KEYPAD RED WIRE
TO KEYPAD GRN WIRE
TO KEYPAD YEL WIRE
Figure 7. Using A Supplementary Power Supply For Keypads
Preliminary Check-out Procedure
If you want to check that the system is working before connecting field wiring
from zones and devices, do the following:
1. Temporarily connect a 2000 ohm end-of-line resistor across each of the basic
hard-wire zones 1–8, as shown in the Summary of Connections diagram.
Without actual zone wiring or EOL resistors connected, the keypads in each
partition of the system will not display the “Ready” message.
2. Power up the system temporarily by plugging the AC transformer (previously
wired to the control) into a 120VAC outlet.
3. Busy Ð Standby (Alpha keypads) or dI (Fixed-word keypads) will be
displayed.
After approximately 1 minute*, the green “READY” LED (or “POWER” LED on
some types of keypads) should light, and the word READY (Fixed-word
keypads), or DISARMED...READY TO ARM (Alpha keypads) should be
displayed.
* To bypass the 1-minute delay, press [#] plus 0.
If the “Ready” display does not appear on any of the keypads in the system (in
either of the partitions), or a “Not Ready” message is displayed, check the
keypad wiring connections, and make sure each of the 8 basic hard-wired
zones has a 2000 ohm resistor connected across its terminals.
4. When you get the proper “Ready” displays on the keypad(s), the system is
functioning properly at this point.
Do not remove the EOL resistors until you are ready to make connections to
the hard-wired zones, to allow for testing later in the manual.
If an OC or OPEN CIRCUIT is present on the keypad, data from the control is not
reaching the keypad. Please check the wiring.