VISTA-250FBP (3/17/2003) 13850 - 5
Detection and Alarm
capable of being assigned the same or a different level of authority
for each partition that it will operate.
b. Opening/Closing central station reporting option.
c. Specific partitions that the code can operate.
d. Global arming capability (ability to arm all partitions the code has
access to in one command).
e. Use of an RF (button) to arm and disarm the system (RF key must
first be enrolled into the system).
5. Peripheral Devices – The control shall support up to 30 addressable ECP
devices, which can be any combination of keypads, RF receivers, relay
modules, annunciator modules, and interactive phone modules. Peripheral
devices have the following characteristics:
a. Each device set to an individual address according to the device's
instructions.
b. Each device enabled in system programming.
c. Each device’s address shall be supervisable (via a programming
option).
6. Keypad/Annunciator – The control shall accommodate up to 16 keypads
or six (6) touch-screen (i.e.; advanced user interface) keypads. The
keypads shall be capable of the following:
a. Performing all system arming functions.
b. Being assigned to any partition.
c. Providing four programmable single-button function keys, which
can be used for:
(1) Panic Functions –activated by wired and wireless keypads;
reported separately by partition.
(2) Keypad Macros –32 keypad macro commands per system
(each macro is a series of keypad commands). Assignable
to the A, B, C, and D keys by partition.
7. Optional Output Relays - A total of 96 relay outputs shall be
accommodated using relay modules. Each relay module shall provide four
(4) Form C (normally open and normally closed) relays for general-
purpose use or two (2) Class-B, Style-Y supervised notification appliance
circuit outputs, when using the 4204CF module. The relays shall be
capable of being:
a. Programmed to activate in response to system events.
b. Programmed to activate using time intervals.