Chapter 3: Alarm Panel Configuration Settings
Section 3.1: Vista-10/15/20 Programming
To setup the Honeywell Vista 10/15/20 Series panels to output signals to Virtual Monitoring
network systems the following configuration options must be addressed:
Enter Programming (installer code 8 00) Default installer code is 4112. You will see 20 or
Installer Code 20 on the keypad display. To advance to a programming field, press * then the
field number. If you do not know the installer code and 4112 8 00 does not get you into
programming, email info@virtualmonitoring.biz with your user name and we will send you
instructions for getting into programming.
• *29 (Long Range Radio Output: Enter 1)
The Primary and Secondary Telephone Numbers only needs to be programmed if you are
sending reports via a Standard Phone line to a Central Station in Conjunction with the Virtual
Monitoring Notification Services.
• *41 (Primary Phone No. or Delete if not in use by entering *.)
• *42 (Secondary Phone No. or Delete if not in use by entering *.)
• *43 (Primary Subscriber ID. Input 4 Account No. from your dealer or set to '0000' if not
used.)
• *54 (Dynamic Signaling Enter "0" for Redundant Reporting.)
• *55 (Dynamic Signal Priority Enter "1" for LRR output first.)