– 19 –
How to Assign User Codes and Attributes
Refer to the User Setup chart at the back of this manual to keep a record of user programming.
NOTE: Partition Master codes apply only to those user numbers previously assigned (by the system master/
installer) to the partition master’s partition.
Add User Code: System/Partition Master code + [8] + user no. + new user’s code
(
User 03 is preset to be
User 01 = installer
a partition 1 programmer,
User 02 = master
but can be changed.)
User 03 = partition 1 master
The Keypad beeps once to confirm that new user was added.
Delete User Code: System/Partition Master code + [8] + [user no.] + [#] + [0]
The user code and all attributes* programmed for this user number, including any
associated RF keys, are erased from the system. (*except assigned partition)
Authority Level: System/Partition Master code + [8] + [user no.] + [#] + [1]+ auth. level
Factory Assignments: Authority Levels (see definitions above):
(Users 04-17 = 0
0 = standard user;
user 03 = 4)
1 = arm only;
2 = guest;
3 = duress;
4 = partition master
Access Group: System/Partition Master Code + [8] + [user no.] + [#] + [2]+ group (1-8)
Factory Assignments: none You can assign users to a group, then set an access schedule that defines the times this
group of users can operate the system. The system does not allow these users to control
the system outside the scheduled times.
User’s Partition: System Master Code + [8] + [user no.] + [#] + [3] + [0] + partition(s) + [#]
Factory Assignments: This command assigns the partitions the user can access. If more
Part. 1 = users 03-17 than one, enter partition numbers sequentially, then press [#] to end.
E.g., master code + [8] + [user no.] + [#] [3] + [0] + [1] [2] + [#] gives
the user access to partitions 1 and 2.
Partition Entries: 1 = partition 1; 2 = partition 2; 3 = common partition
RF User Number: Master/Part. Prog. Code + [8] + [user no.] + [#] + [4]+ zone no.
Factory Assignments: none Use this command to assign a wireless button device (keyfob) to this user (keyfob
must be enrolled in system first; see installer).
Zone number: Enter the zone number assigned to the desired function button on the
keyfob that will be used by this user. Each button was assigned a unique zone
number. See your installer for appropriate zone numbers.
Arm/Disarm Report: Master/Part. Prog. Code + [8] + [user no.] + [#] + [6] + 0 or 1
You can program a user so that a message is sent to the monitoring station whenever
this code is used to arm or disarm the system. 1 = send arm/disarm report; 0 = no
arm/disarm reporting for this user
Comentarios a estos manuales