ADEMCO Vista-128B PLUS Manual de usuario Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 39
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
– 8 –
*37
DOWNLOAD COMMAND ENABLES
0
Dialer System Not Remote Remote Remote UploadDownload
Shutdwn Shutdwn Used Bypass Disarm Arm Program Program
See field 1*53 for Callback disable option; [1=enable];
0=disable; For UL installations, all entries must be "0."
*38
PREVENT ZONE XXX BYPASS [000]
| |
001-128; 00 if all zones can be bypassed
*39
ENABLE OPEN/CLOSE REPORT FOR [1]
INSTALLER CODE
1=enable; 0=disable
*40
OPEN/CLOSE REPORT FOR KEYSWITCH [0]
1=enable; 0=disable
*
41
NORMALLY CLOSED or EOLR (Zones 2-8) [0]
1=N.C.loops; 0=EOLR supervision; Must be "0" for UL
Commercial.
*42
DIAL TONE PAUSE [0]
0=5 seconds; 1=11 seconds; 2=30 seconds; Must be
"0" UL Commercial.
*43
DIAL TONE DETECTION [1]
1=wait for true dial tone; 0=pause, then dial
*44
RING DETECTION COUNT [00]
|
01-14; 15=answering machine; 00=no detection. Must
be "00" for UL Commercial Burglary.
*45
PRIMARY FORMAT [0]
0=Low Speed; 1=Contact ID; 2=Ademco High
Speed
;
3=Ademco Express
*46
LOW SPEED FORMAT (Primary) [0]
0=Ademco Low Speed; 1=Sescoa/Radionics
*47
SECONDARY FORMAT [0]
0=Low Speed; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
*48
LOW SPEED FORMAT (Sec.) [0]
0=Ademco Low Speed; 1=Sescoa/Radionics
*49
CHECKSUM VERIFICATION [0] [0]
1=yes; 0=no Prim Sec
*50
SESCOA/RADIONICS SELECT [0]
1=Sescoa; 0=Radionics
*51
DUAL REPORTING [0]
1=yes; 0=no If used with Spilt Reporting "1" option (1*34),
alarms and alarm restores go to both primary & secondary
numbers, while all other reports go to secondary only. If used
with Split Reporting "2" option, alarms and alarm restores go
to both, open/close and test messages go to secondary only,
while all other reports go to primary.
*52
STANDARD/EXPANDED REPORT FOR PRIMARY
[0 0 0 0 0 0]
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
0=standard; 1=expanded;
Note: Expanded overrides 4+2 format.
*53
STANDARD/EXPANDED REPORT FOR SECONDARY
[0 0 0 0 0 0]
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
0=standard; 1=expanded;
Note: Expanded overrides 4+2 format.
*56
USE ONLY LRR (LONG RANGE RADIO) [0]
0=No, 1=Yes, if built-in dialer will not be used.
*57
USE LRR IF DIALER FAILS [0]
0=No, 1=Yes, if radio is to be used as a backup to dialer
*58
LRR CENTRAL STATION #1 CATEGORY ENABLE
[0 0 0 0 0 0]
Alrm Trbl Byp O/C Syst Tst
0=disable, 1=enable for reports for primary subs id of LRR
*59
LRR CENTRAL STATION #2 CATEGORY ENABLE
[0 0 0 0 0 0]
Alrm Trbl Byp O/C Syst Tst
0=disable, 1=enable for reports for secondary subs id of LRR
*64
PAGER INSTALLED [0]
0=No, 1=Yes, alpha numeric pager interface is installed.
*65
PAGER PHONE # FOR ALARMS
Enter 0-9 for each digit; #11 for *; #12 for #; #13 for 2 sec. pause.
*66
PAGER ID # FOR ALARMS
Enter up to 10 digits for the pager id #
*67
PAGER PHONE # FOR TROUBLES
Enter 0-9 for each digit; #11 for *; #12 for #; #13 for 2 sec. pause.
*68
PAGER ID # FOR TROUBLES
Enter up to 10 digits for the pager id #
*69
PAGER PHONE # FOR BYPASSES
Enter 0-9 for each digit; #11 for *; #12 for #; #13 for 2 sec. pause.
*70
PAGER ID # FOR BYPASSES
Enter up to 10 digits for the pager id #
*71
PAGER PHONE # FOR OPENS/CLOSES
Enter 0-9 for each digit; #11 for *; #12 for #; #13 for 2 sec. pause.
*72
PAGER ID # FOR OPENS/CLOSES
Enter up to 10 digits for the pager id #
Vista de pagina 6