Programming With #93 Menu Mode
NOTE: The following field should be preset before beginning: 2*00 Number of Partitions. In addition, receivers
should be programmed via Device programming.
After programming all system related programming fields in the usual way, press #93 while still in programming mode to
display the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed
menu selection. Pressing 0 will display the next choice in sequence. Menu selections are as follows:
ZONE PROG?
0=No 1=Yes
For programming the following:
Zone Number
Zone Response Type
Partition Number for Zone
Dialer report code for zone
Input Device Type for zone (whether RF, polling loop, etc.)
Enrolling serial numbers of 5800 series transmitters & serial polling loop devices into the
system.
SEQUENTIAL LEARN?
0=No 1=Yes
For programming the following:
Input Device Type for zone (whether RF, polling loop, etc.)
Enrolling serial numbers of 5800 series transmitters & serial polling loop devices into the
system (all other zone characteristics must be pre-programmed).
REPORT CODE PROG?
0=No 1=Yes
For programming the following:
Alarm report codes for zones
Restore & supervisory codes
All other system report codes
ALPHA PROG?
0=No 1=Yes
For entering alpha descriptors for the following:
Zone Descriptors
Installer's Message
Custom Words
Partition Descriptors
Relay Descriptors
DEVICE PROG?
0=No 1=Yes
For defining the following device characteristics for addressable devices, including keypads,
RF receivers (5881), output relay modules (4204/4204CF), 4285/4286 VIP Module, ECP
long range radio (7820), and vista gateway module:
Device Address
Device Type
Keypad Options (incl. partition assignment)
RF House ID
LRR Options (incl. programming radio)
RELAY PROG?
0=No 1=Yes
For defining output relay functions.
RLY VOICE DESCR?
0=No 1=Yes
For entering voice descriptors for relays to be used with the 4285/4286 VIP Module.
CUSTOM INDEX ?
0=No 1=Yes
For creating custom word substitutes for VIP Module annunciation.
CLEAR RF SERIAL#?
1=Yes 0=No
For deleting all RF serial numbers presently in the system, if an undesired transmitter has
been enrolled during sequential enrolling.
#93 MENU MODE KEY COMMANDS
The following is a list of commands used while in the menu mode.
#93 Enters Menu mode
[] Serves as ENTER key. Press to have keypad accept entry.
[#] Backs up to previous screen.
0 Press to answer NO
1 Press to answer YES
001-009 All data entries are either 2-digit or 3-digit entries.
000 Exits menu mode, back into field programming mode, when entered at the first question for each category.