– 7 –
VISTA 128B Programming Form
Some fields are programmed for each partition (shown as shaded fields). If Programming a Multiple Partition System, see the
PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown in brackets [ ],
otherwise default = 0.
*00
INSTALLER CODE
| | |
Enter 4 digits, 0-9 [4140]
*09
ENTRY DELAY #1 [02]
|
00-15 times 15 seconds
Maximum "03" for UL Commercial Burglary.
*10
EXIT DELAY #1 [03]
|
00-15 times 15 seconds
Maximum "04" for UL Listed installations.
*11
ENTRY DELAY #2 [06]
|
00-15 times 15 seconds (must be longer than Entry Delay #1).
Maximum "03" for UL Commercial Burglary installations.
*12
EXIT DELAY #2 [08]
|
00-15 times 15 seconds (must be longer than Exit Delay #1)
Maximum "04" for UL Commercial Burglary installations.
*13
BELL TIMEOUT [04]
|
01-15 times 2 minutes. Minimum 16 min. for UL Commercial
Burglary.
*14
ZONE 9 RESPONSE TIME
[0]
Enter 1 for fast response (10 msec)
Enter 0 for slow response (350 msec)
*15
KEYSWITCH ASSIGNMENT [0]
Enter partition in which keyswitch used,
1-8; 0=disable
*16
CONFIRMATION OF ARMING DING [0]
1=enable; 0=disable. Must be "1" for UL Burglary
Installations.
*17
AC LOSS KEYPAD SOUNDING [0]
1=yes; 0=no
*19
RANDOMIZE AC LOSS REPORT [0]
1=10-40 min; 2=6-12 hrs; 0=normal report (about 2 min.
after AC loss). Must be "2" for Central and Remote
Station alarm systems.
*20
VIP MODULE PHONE CODE
| |
Enter 01 - 09 for the first digit; enter [00] , [11]
11 for "
*
" or 12 for "#" for the second digit. This field
Must be set to "0" for UL Commercial Burglary
installations.
*21
PREVENT FIRE TIMEOUT [0]
1=No timeout 0=Timeout.
*22
KEYPAD PANIC ENABLE [001]
1=enable; 0=disable
995 996 999
*23
MULTIPLE ALARMS [1]
1=yes; 0=no
*24
IGNORE EXPANSION ZONE TAMPER [0]
1=Ignore; 0=Enable tamper for RF and RPMs. Must be "0" for
UL installations if using these devices.
*25
BURG.TRIGGER FOR RESPONSE TYPE 8 [1]
1=enable; 0=disable
*26
INTELLIGENT TEST REPORTING [0]
1=yes, (no report sent if any other report was recently
sent); 0=no.. Must be 0 for UL Commercial Burglary.
*27
TEST REPORT INTERVAL [024
] | |
Enter interval in hours, 001-999; 000=no report ; Max.
024 for UL Commercial.
*28
POWER UP IN PREVIOUS STATE [1]
1=yes; 0=no; "1" for UL.
*29
QUICK ARM [1]
1=yes; 0=no
*30
DIALER (TOUCHTONE OR ROTARY) [0]
1=TouchTone; 0=rotary
*31
PABX ACCESS CODE
| | | |
00-09; B-F (11-15)
*32
PRIM. SUBS. ACCT #
| | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
*33
PRIMARY PHONE NUMBER
Enter 0-9 for each digit. Enter #11 for *, #12 for #,
#13 for 2 second pause
*34
SECONDARY PHONE NUMBER
Enter 0-9 for each digit. Enter #11 for *, #12 for #,
#13 for 2 second pause
*35
DOWNLOAD PHONE No.
Enter 0-9 for each digit. Enter #11 for *, #12 for #,
#13 for 2 second pause
*36
DOWNLOAD ID No.
|
| | | | | | |
Enter 00-09; A-F (10-15) [15 15 15 15 15 15 15 15]