ADEMCO VISTA-50PEN Instrucciones de operaciones Pagina 64

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 63
64
Trouble Conditions
Typical Trouble Displays
The word
CHECK
or
TRBL
on the Keypad's display, accompanied by
a rapid "beeping" at the Keypad, indicates that there is a trouble
condition in the system.
To silence the beeping sound
for trouble conditions, press any key.
A display of
CHECK
or
TRBL
accompanied by a display of
"
CALL SERVICE
" indicates that a problem exists with the
system that eliminates some of the protection. CALL FOR
SERVICE IMMEDIATELY.
A display of
CHECK
or
TRBL
" accompanied by a display of
one or more zone descriptors indicates that a problem exists with
those zone(s)*. First, determine if the zone(s) displayed are intact
and make them so if they are not. If the problem has been
corrected, the display of the zone descriptor(s) and
CHECK
or
TRBL
should disappear. If not, key an OFF sequence (Code plus
OFF) to clear the display. If the display persists, CALL FOR
SERVICE IMMEDIATELY.
A display of
CHECK
or
TRBL
accompanied by a numeric
display of 6XX, where XX = 01-32, indicates a trouble on a
supervised relay (corresponding relay number 01-32).
A display of
CHECK
or
TRBL
accompanied by a numeric
display of 8XX, where XX = 00-31, indicates a trouble on a
peripheral device (connected to the panels keypad terminals) of a
corresponding device address (00-31).