Using #77 Instant Activation Mode (contd)
Bypass Commands
Activation times
1
(Beginning),
2
(End),
3
(During) are the only valid
choices for bypass commands. If
3
(During) is selected for auto-
bypassing, the system bypasses the zone(s) specified on a particular
zone list at the beginning of the window and unbypasses the zone(s) at
the end of the window. If it is selected for auto unbypassing, the
system removes the bypass of the zone(s) at the beginning of the
window and restores the bypass of the zone(s) at the end of the
window.
Action Code
Action Specifier
30 Auto bypass - Zone list Zone list #
31 Auto unbypass - Zone list Zone list #
Open/Close Windows
Activation time
3
(During) is the only valid choice for these
commands.
Action Code
Action Specifier
40 Enable Opening Window by partition Partition(s)
41 Enable Closing Window by partition Partition(s)
42 Enable Access Window for access group Access Group
50 Off-Normal Reminder None
(Starts local keypad beeping if fire off-normal condition exists)
Access Control Commands (for use with VistaKey modules only)
Action Code
Action Specifier
55 Access Point Grant Access Point #
56 Access Point Grant with Override Access Point #
57 Access Point Protect Access Point #
58 Access Point Bypass Access Point #
59 Access Point Lock Access Point #
60 Access Point Exit Access Point #
61 Access Point Group Grant Group #
62 Access Point Group Grant with Override Group #
63 Access Point Group Protect Group #
64 Access Point Group Bypass Group #