Vista 20SEa Training Guide Page 6
Vista 20a
8 Basic wired zones
Vista 20SEa
8 Basic wired zones
Wireless Transmitters
This procedure is not required for the Vista 20a
No QED feature (Quick Enrolment Device)
Wireless Transmitters
Note: When programming a RF transmitter, the
loop number must be typed in manually, before
learning in the serial number
Once serial number has been enrolled and
confirmed by the system press “*” to display
Zone summary.
Note: The QED mode also allows a button
transmitter such as 5804, to be used as a
“Programming tool”
Mains Power Supply
16vac 1.5amp plug pack
The Same as Vista 20a
Back-up Battery
12vdc 7ah sealed Rechargeable type
The Same as Vista 20a
Chime
Only per partition (User mode)
Note: Chime mode does not apply to Zone Type
04 or Zone Type 10.
Chime
Can be programmed by zone (field *26).
(Program zones to chime in Zone List 3)
Can be programmed by partition (User mode)
Note: Chime mode does not apply to Zone Type
04 or Zone Type 10 (These are Interior types).
No Event log available Event Logging (field *88)
The Vista 20SEa has the ability to record various
events in a History Log (up to 48-event capacity)
0 = None (to disable) 1 = Alarm/Alarm Restore
2 = Trouble Restore 4 = Bypass/Bypass Restore
8 = Open/Close #15 = Selects All
Default is 3 = (1+2)
Event log is only viewable through down-loader
Event Log 80% Full Report Enable (field *89)
It also can notify the central station when the
Event Log is 80% Full (this feature is also enabled
by default, to disabled this feature type in “00”).
Entry & Exit Delay
Zone type 01 Entry delay is partition specific.
0 = 0 seconds 1 = 20 seconds 2 = 30 seconds
3 = 45 seconds 4 = 60 seconds 5 = 90 seconds
Zone type 02 Entry delay = Zone type 01 Entry
delay + 30 seconds.
Exit delays = Entry delay + 40 seconds.
Note: Exit delay time selected is common for both
Zone type 01 and Zone type 02.
Zone type 01 Entry delay, Zone type 02 Entry
delay and Exit delay are all programmed from
field *35.
Entry & Exit Delay
Zone type 01 Entry delay is also partition
specific. Entry delay time of 00 99 seconds can
be selected individually per partition (field *35)
Zone type 02 Entry delay is also partition
specific. Entry delay time of 00 99 seconds can
be selected individually per partition (field *36)
Exit delay is also partition specific. Exit delay
time of 00 99 seconds can be selected
individually per partition (field *34)
Note: Exit delay time selected will be common for
both Zone type 01 and Zone type 02.