Vista 20a
8 Basic wired zones
Vista 20SEa
8 Basic wired zones
Optional Siren / Bell Supervision
Not Available on Vista 20a
Optional Siren / Bell Supervision
( Console beeps and displays check 70 while
panel dials and sends a Contact id event for
siren/bell tamper )
Confirmation of Arming Ding
Location *38
Enter 1 (in either or both partitions) to enable ½
second external alarm sounding “Ding” at Kiss off
(when closing report goes in), or at the end of exit
time if Open and Close (Arm away only) is not
enabled.
Enter 0 in this location to disable this feature.
Confirmation of Arming Ding
Location *38
Enter 1 (in either or both partitions) to enable ½
second external alarm sounding “Ding” at Kiss off
(when closing report goes in), or at the end of exit
time if Open and Close (Arm away only) is not
enabled.
Enter 2 for RF key arming only notification “Ding”.
Note: The ½ second “Ding” will occur instantly
when armed away by RF key, even If the open
and close reports are enabled, It doesn’t wait for
the end of exit time.
Enter 0 in this location to disable this feature
Option Selection
(Field *91)
Enter “0” if an AAV unit is not being used
(default)
Enter “4” if an Audio Alarm Verification (AAV)
unit is connected.
Option Selection
(Field *91)
Enter “0” if not being used (default).
Enter “1” To restrict User code #15 option for
Open/Close Reporting (applies for both
partitions).
Enter “4” if an Audio Alarm Verification (AAV)
unit is connected.
Enter “8” To enable Exit Delay Restart.
This feature is only applicable, if armed in the
STAY or INSTANT mode (See User Guide).
You can Restart the Exit Delay at any time after
arming in the INSTANT or STAY mode by
pressing the “*” Key.
Example: For restricted User #15 Open/Close
Reporting and to enable Exit Delay restart, press
“9” = 1 + 8 options.
Auxiliary Power Output The Same as Vista 20a
Download Programming (V-link and Compass)
Download Programming (Compass only)
Communication Format Supported
Ademco Contact ID & Audio
The Same as Vista 20a
Zone type 10
(Perimeter Burglary with pre-Alarm)
A trip on this Zone type will start Entry delay #1, if
tripped when the panel is armed in the STAY or
INSTANT modes, regardless of weather or not an
Entry/Exit delay zone was tripped first.
Note: No pre-alarm delay is provided if tripped
when panel is armed in the AWAY or MAXIMUM
modes.
Zone type 10
(Interior With Delay)
A trip on this Zone type will start Entry delay #1, if
tripped when the panel is armed in the AWAY
mode, regardless of weather or not an Entry/Exit
delay zone was tripped first.
Note: This type of Zone is bypassed when the
panel is armed in the STAY or INSTANT mode.
No pre-alarm delay is provided if tripped when
panel is armed in the MAXIMUM mode.