Vista 20SEa Training Guide Page 10
4.1 Programming
* 8 Zones Hardwired
* Back to Base (Ademco Contact ID)
* Quick Arming
* 8 Minutes Siren time out
Enter Programming Mode Press "
" & "#" within 50 Seconds of Power up OR Enter Installer Code (4112) + "8" + "0" + "0"
Pre Sets
* 9 7 Loads Factory Defaults
(Previous programming will be erased)
Pre Sets
* 9 6
Resets the Subscriber Account number and CSID. MUST BE DONE
*20
Installer Code
*21
Quick Arm Enable
(Only program for PABX access ie.. dial 0 to get a line)
*41
Primary Phone Number:
*41*
*42
Secondary Phone Number:
Enter up to 16 digits (For local Alarms enter
*42*
Primary Subscriber ID - Partition 1
Secondary Subscriber ID - Partition 1
Primary Subscriber ID Partition 2
Secondary Subscriber ID Partition 2
*47
Phone System Select
("1" = Tone Dial, "0" = Pulse Dial)
*51
Periodic Test Report
("2" = weekly test reports, "1" = 24 hourly test reports)
*52
Test Report Offset
("0" = none, "1" = 6 hours, "2" = 12 hours, "3" = 18 hours)
*56
Zone Assignment
*66
Arm Away/Stay Report Enable
*94
Download Phone Number
*95
Ring Detection Count for Downloading
("# 15" = Answering System Defeat)
* 9 9
Zone Assignment
For Zone Programming Enter *56 then Enter required Zone Number.
Zone Types
VISTA 20SEa Quickstart Programming Sheet
Follow this Guide to set up your Vista 20SEa with the following options:
To Enable Siren Monitoring, Cut Link on
Circuit board.
See Wiring diagram for more detail
ON IN STAY MODE
Type 01 Entry / Exit Burglary #1
Type 02 Entry / Exit Burglary #2
Type 03 Perimeter Burglary
OFF IN STAY MODE
Type 04 Interior Follower
Type 10 Interior with Delay
WIRELESS ONLY
Type 20 Arm - Stay
Type 21 Arm - Away
Type 22 Disarming
Type 23 No Alarm Response
Z n Z T P R C I n : L
0 1 0 1 01 1 0 HW: 1
Zn = Zone Number
ZT = Zone Type
RC = Report Code
In = Input Type
Loop Number
ZONE DEFAULTS
Zone 1 = (01) Entry / Exit Burglary #1
Zone 2 = (04) Interior Follower
Zone 3 = (03) Perimeter Burglary
Zone 4 = (03) Perimeter Burglary
Zone 5 = (03) Perimeter Burglary
Zone 6 = (03) Perimeter Burglary
Zone 7 = (03) Perimeter Burglary
Zone 8 = (03) Perimeter Burglary
Zone 9 = (05) Trb Day / Alm Ngt
Expansion Module Supervision
Zone 92 = Duress Enabled
Zone 99 = (06) 24 Hr Silent (* & #) Panic
24 HOUR ZONES
Type 05 Trouble Day / Alarm Night
Type 06 24 Hour Silent Alarm
Type 07 24 Hour Audible Alarm
Type 08 24 Hour Auxiliary Alarm