ADEMCO VISTA-20SE Guía de usuario Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
Vista 20SEa Training Guide Page 10
4.1 Programming
* 8 Zones Hardwired
* Back to Base (Ademco Contact ID)
* Forced Arming
* Weekly test Reports
* Quick Arming
* 30 Secs Entry Time
* 8 Minutes Siren time out
* 70 Secs Exit Time
Field
Entry
Function ( comments )
Enter Programming Mode Press "
*
" & "#" within 50 Seconds of Power up OR Enter Installer Code (4112) + "8" + "0" + "0"
Pre Sets
* 9 7 Loads Factory Defaults
(Previous programming will be erased)
MUST BE DONE
Pre Sets
* 9 6
Resets the Subscriber Account number and CSID. MUST BE DONE
*20
?
?
?
?
Installer Code
(Default = 4 1 1 2)
*21
1
1
Quick Arm Enable
("1" = Yes, "0" = No)
*40
?
?
?
*
PABX Code:
(Only program for PABX access ie.. dial 0 to get a line)
*41
?
?
?
?
?
?
?
?
?
?
?
*
Primary Phone Number:
Enter up to 16 digits
(For local Alarms enter
*41*
)
*42
?
?
?
?
?
?
?
?
?
?
?
*
Secondary Phone Number:
Enter up to 16 digits (For local Alarms enter
*42*
)
*43
?
?
?
?
Primary Subscriber ID - Partition 1
(Enter 4 digits)
*44
?
?
?
?
Secondary Subscriber ID - Partition 1
(Enter 4 digits)
*45
?
?
?
?
Primary Subscriber ID Partition 2
(Enter 4 digits)
*46
?
?
?
?
Secondary Subscriber ID Partition 2
(Enter 4 digits)
*47
1
Phone System Select
("1" = Tone Dial, "0" = Pulse Dial)
*51
2
Periodic Test Report
("2" = weekly test reports, "1" = 24 hourly test reports)
*52
2
Test Report Offset
("0" = none, "1" = 6 hours, "2" = 12 hours, "3" = 18 hours)
*56
Interactive Field
Zone Assignment
(see Below)
*66
0
0
0
0
Arm Away/Stay Report Enable
("00" = disable report)
*94
A
S
R
E
Q
U
I
R
E
D
*
Download Phone Number
*95
0
Ring Detection Count for Downloading
("# 15" = Answering System Defeat)
Exit
* 9 9
Exits Programming mode
Zone Assignment
For Zone Programming Enter *56 then Enter required Zone Number.
Zone Types
VISTA 20SEa Quickstart Programming Sheet
Follow this Guide to set up your Vista 20SEa with the following options:
To Enable Siren Monitoring, Cut Link on
Circuit board.
See Wiring diagram for more detail
ON IN STAY MODE
Type 01 Entry / Exit Burglary #1
Type 02 Entry / Exit Burglary #2
Type 03 Perimeter Burglary
OFF IN STAY MODE
Type 04 Interior Follower
Type 10 Interior with Delay
WIRELESS ONLY
Type 20 Arm - Stay
Type 21 Arm - Away
Type 22 Disarming
Type 23 No Alarm Response
Z n Z T P R C I n : L
0 1 0 1 01 1 0 HW: 1
Zn = Zone Number
ZT = Zone Type
RC = Report Code
In = Input Type
L = Response Time or
Loop Number
ZONE DEFAULTS
Zone 1 = (01) Entry / Exit Burglary #1
Zone 2 = (04) Interior Follower
Zone 3 = (03) Perimeter Burglary
Zone 4 = (03) Perimeter Burglary
Zone 5 = (03) Perimeter Burglary
Zone 6 = (03) Perimeter Burglary
Zone 7 = (03) Perimeter Burglary
Zone 8 = (03) Perimeter Burglary
Zone 9 = (05) Trb Day / Alm Ngt
Expansion Module Supervision
Zone 92 = Duress Enabled
Zone 99 = (06) 24 Hr Silent (* & #) Panic
24 HOUR ZONES
Type 05 Trouble Day / Alarm Night
Type 06 24 Hour Silent Alarm
Type 07 24 Hour Audible Alarm
Type 08 24 Hour Auxiliary Alarm
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 33 34

Comentarios a estos manuales

Sin comentarios