– 2 –
TABLE OF CONTENTS
RECOMMENDED PROGRAMMING PROCEDURE................................................................................. 3
PROGRAM FIELD CATEGORIES ............................................................................................................. 5
VISTA-100 SINGLE PARTITION PROGRAMMING FORM...................................................................... 6
VISTA-100 MULTIPLE-PARTITION PROGRAMMING FORM................................................................ 10
PROGRAMMING WITH #93 MENU MODE............................................................................................. 15
SYSTEM LAYOUT WORKSHEETS ........................................................................................................ 16
The purpose of this document is to provide a quick and easy way to program your entire system. A
recommended programming procedure is included, followed by a list of program fields with the
corresponding program group they belong to (system-wide, partition-specific, scheduling, etc.). Two
program forms are included, one for a single-partition system, and the other for a multiple partition system.
If you are setting up a single-partition system, the partition-specific fields become system-wide fields.
Following the program forms are system layout worksheets. We recommend that you use these sheets
to plan your system before programming is performed. If you need further information about specific
programming options, see the VISTA-100 INSTALLATION INSTRUCTIONS.
Two programming forms are provided: Single Partition Form and Multiple-Partition Form
Make sure that one two-line alpha keypad is connected to the control and is set to device
address "00."
Single Partition System
The system default is for a single partition system. Use the VISTA-100 SINGLE PARTITION
PROGRAMMING FORM beginning on page 6 when programming for single partition usage.
Follow the steps outlined on page 3 of this document for proper programming procedure.
Multiple-Partition System
You must enter the number of partitions you are using in data field 2*00 to set the system for
multiple partitions. Use the VISTA-100 MULTIPLE-PARTITION PROGRAMMING FORM
beginning on page 10 when programming the system for multiple partitions. Follow the steps
outlined on page 3 of this document for proper programming procedure.
SUMMARY OF PROGRAMMING COMMANDS
To enter program mode, enter installer code + [8] + [0] + [0] + [0]
To set standard defaults, press *97
To set communication defaults, press *94 + one of the following: *80=low speed; *81=Ademco
Express; *82=Ademco High Speed; *83=Ademco's Contact ID
To change to next page of program fields, press *94
To return to previous set of fields, press *99
To erase account & phone number field entries, press [*] + field number + [*]
To assign zone descriptors, press #93 + follow menu prompts
To add custom words, press #93 + follow menu prompts
To enter Installer's Message, press #93 + follow menu prompts
To exit program mode, press *99 OR *98: *99 allows re-access to programming mode by installer code.
*98 prevents re-access to programming mode by installer code.
Standard default (*97) values are shown in brackets [ ], otherwise default = 0.