PROGRAMMING WITH #93 MENU MODE
NOTE: The following fields should be preset before beginning: 2*00 Number of Partitions;
1*32 receiver type. In addition, receivers should be programmed via Device programming.
After programming all system related programming fields in the usual way, press #93 while still in programming
mode to display the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to
the displayed menu selection. Pressing 0 will display the next choice in sequence. Menu selections are as follows:
ZONE PROG?
0=No 1=Yes
For programming the following:
Zone Number
Zone Response Type
Hardwired zone
RF Zone
Right/left Loop Zone
Serial number RPM zone
Partition Number for Zone
Dialer report code for zone
SERIAL PROG?
0=no 1=yes
For entering (learning) 5800 transmitter & serial number polling loop device serial
numbers into the system.
REPORT CODE PROG
0 = no; 1 = yes
For entering report codes for zones and all system conditions.
ALPHA PROG?
0=no 1=yes
For entering alpha descriptors for the following:
Zone Descriptors
Installer's Message
Custom Words
Partition Descriptors
Relay Descriptors
DEVICE PROG?
0=no 1=yes
For defining the following device characteristics for addressable devices, including
consoles, RF receivers (4281/5881), 4285 voice module and 4204 output relay modules:
Device Address
Device Type
Device's Home Partition
Console Options
Voice Module
RELAY PROG?
0=no 1=yes
For defining output relay functions.
RLY VOICE DESCR?
0=no 1=yes
For entering voice descriptors to be used with voice module functions.
CUSTOM INDEX #?
0=no 1=yes
For creating custom word substitutes for voice module annunciation.
#93 MENU MODE KEY COMMANDS
The following is a list of commands used while in the menu mode.
#93 Enters Menu mode
[] Serves as ENTER key. Press to have console accept entry.
[#] Backs up to previous screen.
0 Press to answer NO
1 Press to answer YES
01-09 All data entries are 2-digit entries.
00 Escapes from menu mode, back into field programming mode, when entered at the first question for
each category.