– 13 –
PARTITION-SPECIFIC FIELDS
(Duplicate this page for each partition in the installation.)
To program these fields,
1. Press *91 to select a partition.
2. Enter a partition-specific field number (ex. *09).
3. Make the required entry.
4. Repeat steps 1-3 for each partition in the system.
PARTITION #____ PROGRAM FIELDS
1st Page Fields
*09 ENTRY DELAY #1 [02] |
00-15 times 15 seconds
Maximum 03 for UL Listed installations.
*10 EXIT DELAY #1 [03] |
00-15 times 15 seconds
Maximum 04 for UL Listed installations.
*11 ENTRY DELAY #2 [06] |
00-15 times 15 seconds
Maximum 03 for UL Commercial Burglary installations.
*12 EXIT DELAY #2 [08] |
00-15 times 15 seconds
Maximum 04 for UL Commercial Burglary installations.
*13 BELL 1 TIMEOUT [04] |
01-15 times 2 minutes. Minimum 16 minutes for UL. Commercial
Burglary and 6 minutes for Commercial Fire installations.
*16 CONFIRMATION OF ARMING DING [0]
1=enable; 0=disable. Must be "1" for UL Commercial Burglary
installations.
*22 KEYPAD PANIC ENABLES [001]
1=enable; 0=disable 995 996 999
*23 MULTIPLE ALARMS [1]
1=yes; 0=no. Enter 1 for Commercial Fire & UL Commercial
Burglary installations.
*29 QUICK ARM [1]
1=yes; 0=no
*32 PRIM. SUBS. ACCT # | | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
*38 PREVENT ZONE XXX BYPASS [000] | |
001-087; 00 if all zones (except Fire zones) can be bypassed
*39 ENABLE OPEN/CLOSE REPORT [0]
FOR INSTALLER CODE
1=enable; 0=disable
*84 SWINGER SUPPRESSION [15] |
01-15 alarms; Must be "00" (disabled) for Commercial Fire & UL
installations..
*85 ENABLE DIALER REPORTS [0]
FOR PANICS & DURESS 995 996 999 Duress
1=enable; 0=disable
*87 ENTRY WARNING [1]
1=continuous; 0=3 beeps
*88 BURG. ALARM COMM. DELAY [0] |
1=16 seconds; 0=no delay. Must be "0" for UL Commercial Burglary
installations.
*90 SEC. SUBS. ACCT # | | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
1*18 AFFECTS LOBBY [0]
Enter 1 if this partition affects the common lobby;
enter 0 if it does not.
1*19 ARMS LOBBY [0]
Enter 1 if arming this partition attempts to arm lobby;
enter 0 if it does not
2nd Page Fields
1*43 PERM. KEYPAD BACKLIGHT [0]
1=enable; 0=disable When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
1*45 EXIT DELAY SOUNDING [0]
1=enable; 0=disable Produces quick beeping during exit
delay if enabled.
1*47 CHIME ON BELL 1 [0]
1=enable; 0=disable
1*52 SEND CANCEL IF ALARM + OFF [0]
1=no restriction; 0=within Bell Timeout period only
1*76 ACCESS CONTROL RELAY FOR PART. [00] |
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-16; 00=none. Must be "00" for Commercial
Fire & UL.
3rd Page Fields
2*05 AUTO-ARM DELAY [15]
Enter the time between the end of the arming window and the
start of auto-arming warning period, in values of 1-14 times 4
minutes 00=instant; [15=no auto arm at all]. When this delay
expires, the Auto-Arm Warrning Period begins.
2*06 AUTO-ARM WARNING PERIOD [00]
This is the time during which the user is warned to exit the
premises prior to the auto-arming of the system (beeps every
15 seconds; "ALERT" displayed). Enter 01-15 minutes.
00=instant at end of arming delay .
2*07 AUTO-DISARM DELAY [15]
This is the time between the end of the disarming window and
the start of auto-disarming. Enter 01-14 times 4 minutes;
00=instant at end of window; 15=no auto-disarm.
2*08 ENABLE FORCE ARM FOR AUTO-ARM [0]
0=disable; 1=enable.
2*09 OPEN/CLOSE REPORTS BY EXCEPTION [0]
1=enable; 0=disable; If enabled, only openings and closings
occurring outside the scheduled opening/closing windows will
trigger dialer reports. Opening reports will also be suppressed
during the closing window, in order to prevent false reports
when the user arms the system and then reenters the premises
to retrieve a forgotten item.
2*10 ALLOW DISARMING ONLY DURING [0]
ARMING/DISARMING WINDOWS
See system-wide field 2*11 if enabling field 2*10. This feature
adds high security to the installetion.
0=disable; 1=enable
2*18 ENABLE GOTO FOR THIS PARTITION [0]
1=Allow log-on from other partitions; 0=disable