N5944-6V1 Rev B 4/99VISTA-50PVISTA-50PULPARTITIONED SECURITY SYSTEMwith SCHEDULINGINSTALLATION INSTRUCTIONSandPROGRAMMING GUIDE

Pagina 2

–viii–CONVENTIONS USED IN THIS MANUALMAIN SECTION TITLES ARE SHOWN IN REVERSE TYPEBefore you begin using this manual, it is important that you underst

Pagina 3 - TABLE OF CONTENTS

– 88 –Programming Power and AC Options1. With at least one alpha keypad (5137AD/6139) wired and properlyaddressed, power up the system.2. Enter data f

Pagina 4

– 89 –Combined Auxiliary Power, Alarm Output and Polling LoopTotal CurrentStandby AlarmAuxiliary PowerAlarm OutputPolling LoopTOTALBattery

Pagina 5

– 90 –Section 16: FALSE ALARM REDUCTION FEATURESThis section provides the following information:• General information about false alarms• Exit Error

Pagina 6

– 91 –Cross-ZoningThe Cross-Zoning feature is designed so that a combination of two zones mustbe faulted within a five minute period to cause an alarm

Pagina 7

– 92 –Section 17: ZONE TYPE DEFINITIONSThis section provides the following information:• Zone number designations• Zone Type DefinitionsThe VISTA 50

Pagina 8 - LIST OF FIGURES

– 93 –Type 05: Trouble by Day/Alarm by Night.This zone type will give an instant alarm if faulted whenarmed in the Away, Stay, Instant or Maximum (nig

Pagina 9 - HOW TO USE THIS MANUAL

– 94 –Section 18: DATA FIELD DESCRIPTIONSThe following is a description of all data fields provided by this control. If youhave followed earlier ins

Pagina 10

– 95 –*15 KEYSWITCH ASSIGNMENT Enter the partition number 1-8 in which the keyswitch is being used;otherwise, enter 0.Requires the use of zone 7 wi

Pagina 11

– 96 –*23 MULTIPLE ALARMS (partition-specific) Determines whether or not more than one alarm can be sounded in agiven zone during an armed period.

Pagina 12

– 97 –*29 QUICK ARM (partition-specific) Enter 1 to enable arming of the burglary system in AWAY, STAY,INSTANT or MAXIMUM modes by using the # ke

Pagina 13 - Wireless Expansion

– ix –RECOMMENDATIONS FOR PROPER PROTECTIONThe Following Recommendations For The Location Of Fire And Burglary Detection Devices Help ProvideProper Co

Pagina 14 - Device Programming Mode

– 98 –*35 DOWNLOAD PHONE NO. | | | | | | | | | | | | | | | | | This field is applicable only if downloading will be utilized.Ent

Pagina 15

– 99 –*43 DIAL TONE DETECTION Determines whether the control will wait for a true dial tone beforedialing, or if it will wait for a predeterm

Pagina 16

– 100 –*50 SESCOA/RADIONICS SELECT Enter 0 if Radionics format is to be used with hexadecimal 0-9, B-Freporting.Enter 1 if SESCOA format is t

Pagina 17 - DESCRIPTIONS)

– 101 –*83 FIRST TEST REPORT TIME | | | Enter the day (00-07) and time (00-23 hours/00-59 min.) that the firsttest report shall b

Pagina 18

– 102 –1*19 ARMS LOBBY (partition-specific) Enter 1 if arming this partition causes the system to attempt to arm thecommon lobby partition automati

Pagina 19 - COMMON LOBBY

– 103 –1*30 RF RCVR SUPERVISION CHECK-IN INTERVAL Enter the check-in monitoring interval in 2-hour increments.Enter 02-15 times 2 hours (4-30 hour

Pagina 20

– 104 –1*43 PERMANENT KEYPAD DISPLAY BACKLIGHTING (partition-specific)Enter 1 if it is desired that backlighting for the keypad display remain onat

Pagina 21

– 105 –1*57 ENABLE 5800 RF BUTTON GLOBAL ARM Enter 1 to have the system arm/disarm in accordance with the button'suser's global armin

Pagina 22

– 106 –2*00 NUMBER OF PARTITIONS Enter the number of partitions (1-8) to be used in the system.2*01 DAYLIGHT SAVINGS TIME | | START/END MON

Pagina 23

– 107 –2*11 ALLOW DISARM OUTSIDE WINDOW IF ALARM OCCURSUsed only if field 2*10 (partition-specific field) is set to 1.Enter 1 to allow the system t

Pagina 25 - Figure 5

– 108 –Section 19: #93 MENU MODE PROGRAMMINGThis section provides the following information:• #93 Menu Mode main menu options• Zone Programming• Seri

Pagina 26 - Figure 6

– 109 –Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing0 will display the next choice in sequence. Refer to the ZONE PR

Pagina 27 - POWER-UP PROCEDURE

– 110 –Zone Types are as follows:00 Assign for unused zones01 Entry/Exit #1, burglary02 Entry/exit #2,03 Perimeter, burglary04 Interior, follower, bur

Pagina 28

– 111 –20 INPUT S/N :L A000-0000:1If learning the serial number now (entering 1 at thelast prompt), this prompt appears. Fault and restoret

Pagina 29

– 112 –Input typeInput = 0 or 3-6If a serial number for that device has not beenlearned yet, and if the device assigned to that zonenumber has been pr

Pagina 30

– 113 –Programming Alpha DescriptorsGeneral Information• If using a 5137AD or 6139 alpha keypad in the system, you can program auser friendly English

Pagina 31

– 114 –a) Press [#] followed by the 3 digit number of the first word from the fixeddictionary shown later in this section (e.g., [0][1][3] for BACK).

Pagina 32 - ACCESSORIES

– 115 –When the desired character appears, press the [6] key to select it. Thecursor will then move to the right, in position for the next character.

Pagina 33 - Figure 8

– 116 –Custom Message Display (Installer's Message)Normally, when the system is in the disarmed state, the following display ispresent on the key

Pagina 34 - IMPORTANT:

– 117 –ALPHA DESCRIPTOR VOCABULARY(For Entering Alpha Descriptors. To select a word, press [#] followed by the word's 3-digit number.)NOTE: This

Pagina 35

– 1 –Section 1: GENERAL DESCRIPTIONThe VISTA-50P is an 8-Partition alarm control panel that supports up to 86 zones using basic hardwired, pollingloop

Pagina 36

– 118 –Device ProgrammingThis menu is used to program keypads, receivers and relay modules.From Data Field Programming mode, press #93 to display &quo

Pagina 37

– 119 –SOUND OPTIONAddressable keypads can be individuallyprogrammed to suppress arm/disarm beeps,entry/exit beeps and chime mode beeps. This helpspre

Pagina 38 - Figure 10

– 120 –01 ENTER DESC d1From the relay voice descriptor vocabulary list, enterthe 3-digit index number for the first word of the relaydescriptor phras

Pagina 39 - Figure 11

— 121 —Custom Word Substitutes for VIP Module AnnunciationA substitute word can be programmed for each of the 20 custom words used inyour alpha zone d

Pagina 40

– 122 –Section 20: SCHEDULING OPTIONSThis section provides the following information:• Main features of scheduling• Time Window Definitions• Open/Clo

Pagina 41 - Figure 12

– 123–Extend Closing • A user can manually extend the arm (closing) time windowWindow by 1 or 2 hours. This is done by entering a keypad command(secur

Pagina 42

– 124 –Time Windows DefinitionsTime Windows • Scheduled events are based on time windows, which are simplyperiods of time during which an event may ta

Pagina 43

– 125–Open/Close Schedule DefinitionsGeneral • The Open/Close scheduling is controlled by one of threeindividual schedules. Each schedule consists of

Pagina 44

– 126 –Programming with #80 Scheduling Menu ModeThe #80 Scheduling Menu Mode is used to program most of the scheduling andtimed event options.To enter

Pagina 45 - #16 gauge 2400 feet

– 127 –Basic Scheduling Menu StructureTo program schedules, enter Scheduling program mode:[Installer Code] + # + 80.There are 5 sets of scheduling men

Pagina 46 - FINAL POWER-UP PROCEDURE

–2–8 PartitionsProvides the ability to control 8 separate areas independently, each functioningas if it had its own separate control. Partitioning fe

Pagina 47 - FINAL POWER UP PROCEDURE

– 128 –Time Windows Definitions WorksheetThe system provides 20 time windows that are defined with start and stop times.These windows are used for var

Pagina 48

– 129 –Programming Time WindowsEnter Scheduling Mode by entering the installer code + # + 80. The keypad willdisplay the Time Window programming promp

Pagina 49

– 130 –Programming Open/Close SchedulesEach partition can be assigned one daily open/close schedule, plus a holidayopen/close schedule. Temporary sche

Pagina 50

– 131 –Holiday Definitions & Schedule WorksheetThe system provides up to 16 holidays that can be assigned for the system. Eachholiday can be assig

Pagina 51

– 132 –Time-Driven Event WorksheetThese are the schedules used to activate outputs, bypass zones, etc. based on atime schedule. There are 20 of these

Pagina 52

– 133 –Action Code Action Specifier30 Auto bypass - Zone list Zone list #31 Auto

Pagina 53 - (5700/5800 series)

– 134 –Time-Driven Event ProgrammingThe following schedules can be used to activate outputs, bypass zones,arm/disarm the system, etc. based on a time

Pagina 54

– 135 –30=Auto bypass - Zone list31=Auto unbypass - Zone listActions 30-31Enter the zone list number whichcontains the zones to bebypassed or unbypass

Pagina 55 - Device Programming

– 136 –Limitation of Access by Time WorksheetLimitation of Access is a means by which a user's access code is limited toworking during a certain

Pagina 56 - Programming

– 137 –Hol A1 Window 1 ?00:00 00:00 00Enter the first time window number for holidays for whichthis access schedule applies. As the number is keyed

Pagina 57 - Device Address

– 3 –Keypad MacrosAccommodates one keypad macro command per partition (each macro is aseries of keypad commands), which can be assigned to the D key

Pagina 58 - PROGRAMMING WIRELESS ZONES

– 138 –Arm WindowStart Time HH:MMStop Time HH:MM8 Disarm WindowStart Time HH:MMStop Time HH:MMArm WindowStart Time HH:MMStop Time HH:MMProgra

Pagina 59

– 139 –Days ? MTWTFSS Hit 0-7 x xThis is the prompt that actually activates thetemporary schedule, and allows the temporaryschedule to be customi

Pagina 60

– 140 –06 OFF TIME ? 11:45 PMEnter the OFF time in 00:01 - 11:59 format.When the display shows the desired time, press the *key to move to the

Pagina 61

– 141 –Section 21: SYSTEM COMMUNICATIONThis section provides the following information:• The process of a successful transmission• An explanation of

Pagina 62

– 142 –The following describes each format in greater detail.3+1 and 4+1 Standard Formats Comprised of a 3- (or 4-) digit subscriber number and a sing

Pagina 63

– 143 –Ademco Contact ID Reporting takes the following format:CCCC QEEE GG ZZZwhere: CCCC = Customer (subscriber) IDQ = Event qualifier, where:E = new

Pagina 64

– 144 –Loading Communication DefaultsTo help expedite the installation, the system provides 4 different communicationdefaults (Low Speed, Ademco Expre

Pagina 65

– 145 –COMMUNICATION PROGRAMMING GUIDEField # Low Speed Contact ID High Speed Express*46, *48 Choose transmission No effect No effect No effectspeed a

Pagina 66

– 146 –COMMUNICATION DEFAULTS for LOW SPEED FORMAT (*94*80)*45 PRIMARY FORMAT 0 Ademco Low Speed*46 LOW SPEED FORMAT (Primary) 0 Ademco LowSpeed*4

Pagina 67 - Transmitter ID Sniffer Mode

– 147 –COMMUNICATION DEFAULTS for ADEMCO EXPRESS FORMAT (*94*81)*45 PRIMARY FORMAT 3 Ademco Express*46 LOW SPEED FORMAT (Primary) 0 *47 SECONDARY FO

Pagina 68 - Time Driven

–4–SchedulingProvides the following scheduling capabilities:• Open/Close schedules (for control of arming/disarming, and reporting)• Holiday schedules

Pagina 69 - 4204 RELAY MODULE

– 148 –COMMUNICATION DEFAULTS for ADEMCO HIGH SPEED FORMAT (*94*82)*45 PRIMARY FORMAT 2 Ademco High Speed*46 LOW SPEED FORMAT (Primary) 0 *47 SECOND

Pagina 70

– 149–COMMUNICATION DEFAULTS for ADEMCO's CONTACT ID FORMAT (*94*83)*45 PRIMARY FORMAT 1 Ademco Contact ID*46 LOW SPEED FORMAT (Primary) 0 *47

Pagina 71 - restores

– 150 –Section 22: DOWNLOADING PRIMER(Remote Downloading is not a UL Listed feature)This section provides the following information:• General informa

Pagina 72 - STOP (STP):

– 151 –1. The computer calls up the Control panel. (The phone number for eachcustomer is entered into the customer's account file on the computer

Pagina 73

– 152 –Access SecurityAccessing the Control from a remote location is protected against compromise bythe use of 4 levels of protection:1. Security Cod

Pagina 74 - SCHEDULING OPTIONS

– 153 –Connecting a 4100SM Module for Direct Wire DownloadingThe Control can be downloaded without using a modem or telephone line byusing VLink® Soft

Pagina 75

– 154 –Section 23: SETTING THE REAL-TIME CLOCKThis section provides the following information:• General information about the real-time clock• Settin

Pagina 76

– 155 –Section 24: SECURITY ACCESS CODESThis section provides the following information:• General information about security access codes• Definition

Pagina 77 - (VIP) MODULE

– 156 –Open/Close Reporting Note: When adding a user, the system will only promptfor Open/Close reporting capability if the user is being added by the

Pagina 78

– 157 –Level 6: Duress• Sends a silent alarm to a central monitoring station if the user is being forcedto disarm (or arm) the system under threat (on

Pagina 79 - VOICE MODULE

– 5 –Section 2: PLANNING A PARTITIONED SYSTEMThis section provides the following information:• Theory of partitioning• Setting up a partitioned syste

Pagina 80 - DEVICES

– 158 –EXAMPLE OF MULTIPLE PARTITION ACCESSPart 1 Part 2 Part 3 Part 4 Part 5 Part 6 Part 7 Part 8User 3 User 3Level 1 Level 4Master Oper BIn the abov

Pagina 81 - Section 11

– 159 –Multi-Access ?0 = NO , 1 = YESPress 0 (NO) if the user is to have access to this partitiononly. Press 1 (YES) if the user is to have access to

Pagina 82 - Figure 19

– 160 –Adding An RF Key To An Existing UserTo add an RF key to an existing user, or to change a user's global arm option,first delete that user&a

Pagina 83 - MODEL EAGLE SECURITY

– 161 –Section 25: KEYPAD FUNCTIONSThis section provides the following information:• General information about keypad usage• Basic keypad functions•

Pagina 84 - Figure 20

– 162 –Quick Arming: Note that if QUICK ARM is enabled (field *29), the #key can be pressed instead of entering the securitycode, for any of the arm

Pagina 85 - 1 2 3 4 5 6 7 8 9

– 163 –Access ControlIf programmed, one relay may be used for access control in each partition. Therelay is programmed in data field 1*76. To activate

Pagina 86 - 4142TR CABLE

– 164 –Viewing Downloaded MessagesUsers may occasionally receive a message from their installation companydisplayed on an alpha keypad. When this occ

Pagina 87 - CARRIER DEVICES

– 165 –To program that speed key sequence, type the following :*2 D 61011 D 4D*1 D DNote that the "D" key is pressed after the "2,"

Pagina 88

– 166 –Section 26: TESTING THE SYSTEMThis section provides the following information:• Using Test Mode• Turning the system over to the user• Trouble

Pagina 89 - Figure 23

– 167 –Armed System Test1. A message will be sent to the central station during the following tests. Notifythe central station that a test will be in

Pagina 90

–6–Common Lobby LogicWhen an installation consists of a partition shared by users of other partitions in abuilding, that shared partition may be assig

Pagina 91 - 2.8A maximum

– 168 –Trouble ConditionsThe word "CHECK" on the keypad's display, accompanied by a rapid "beeping"at the keypad, indicates t

Pagina 92 - Figure 26

– 169 –Other System Messages• "COMM. FAILURE" (alpha) or "FC" (fixed-word) at the KeypadIndicates that a failure occurred in the t

Pagina 93

– 170 –REGULATORY AGENCY STATEMENTSUL INSTALLATION REQUIREMENTSThe following requirements apply to both UL Residential and UL CommercialBurglary insta

Pagina 94 - Section 14: EVENT LOG OPTIONS

– 171 –UL611/UL1610 CENTRAL STATION BURGLARY ALARM1. Follow the instructions for UL609 Local installations given above.For Grade A Service:• You must

Pagina 95 - SETTING THE REAL TIME CLOCK

– 172 –"FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT"This equipment has been tested to FCC requirements and has been found acceptable f

Pagina 96

– 173 –CANADIAN DEPARTMENT OF COMMUNICATIONS(DOC) STATEMENTNOTICEThe Canadian Department of Communications label identifies certified equipment. This

Pagina 97 - 0=NO 1=YES

– 174 –DIP SWITCH TABLESDIP SWITCH TABLES FOR ADDRESSABLE POLLING LOOP DEVICES4208 ZONE EXPANDERDIPSHOWN SET FORID 10 (A)SIDE VIEW(UP)12345UPDNUPDNPOS

Pagina 98 - Figure 29

– 175 –DIP SWITCH TABLES FOR POLLING LOOP DEVICES4275 PIRMIRRORDIPSHOWN SET FORID 10 (A)SIDE VIEW(UP)1234567UPDNPOS 6: UP (A), DN (B) = INST. MODEDN

Pagina 99 - RED (+)BLK (–)

– 176 –DIP SWITCH TABLES FOR 5700 RF SYSTEM WIRELESS DEVICESHOUSE ID (1 SHOWN)HOUSE ID (1 SHOWN)HOUSE ID (1 SHOWN)123456UPDN12345UPDN12345678UPDN12345

Pagina 100 - THE MECHANICS OF PROGRAMMING

– 177 –SUMMARY OF SYSTEM COMMANDSEvent Logging Commands(Alpha keypad only)Event Log Display = Code+[#] + 60Event Log Print = Code + [#] +61 (Installer

Pagina 101 - Battery Calculation Worksheet

– 7 –ExampleHere is an example of how the lobby would react in a typical setup.MAIN ENTRANCEOFFICE #1 OFFICE #2COMMON LOBBYUser #1 has access to Offic

Pagina 102

– 178 –SPECIFICATIONSVISTA 50P/VISTA 50PUL CONTROLSPhysical: 12-1/2"W X 14-1/2"H X 3"D (VISTA 50P)14-1/2"W X 18"H X 4.3"

Pagina 103

– 179 –CONTACTING TECHNICAL SUPPORTPLEASE,Before you call Technical Support, be sure you:¥ READ THE INSTRUCTIONS!¥ Check all wiring connections.¥ Dete

Pagina 104

– 180 –INDEXASCII CHART ... 117Supervised RF ... 495711 ...

Pagina 105

– 181 –Interior, Follower ... 92J7 ... 82J8...

Pagina 106

– 182 –WARNING!THE LIMITATIONS OF THIS ALARM SYSTEMWhile this System is an advanced wireless security system, it does not offer guaranteed protection

Pagina 107 - 95 96 99

– 183 –++–N.C.N.C.N.O.2k EOLR(note 1)2k EOLR(note 1)+–+–+–BELLSIRENNO CONNECTIONTRANSFORMER16.5VAC, 40VAADEMCO No.1361(IN CANADAUSE No. 1361CN)or 4300

Pagina 108

àN5944-6V1<äN5944-6V1 Rev B 4/99ADEMCO LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation, and its divisions, s

Pagina 110

–8–How User Access Codes Affect the Common LobbyCodes with "Global" ArmingIf a code is given "global arming" when it is defined (s

Pagina 111

– 9 –The following is an example of a typical display:S Y S T E M 1 2 3 4 5 6 7 8S T A T U S R R N N A * BPossible status indications include:A =

Pagina 112 - 12345678

–10–Section 3: INSTALLING THE CONTROLThis section provides installation instructions for the following:• Mounting the control cabinet• Installing the

Pagina 113 - 95 96 99 Duress

– 11 –Grade A Mercantile Premises Listing• The panel door must be supervised. Mount the clip-on tamper switch(supplied) to the cabinet's right s

Pagina 114

–12–Installing the Control's Circuit BoardRefer to the diagram below when mounting the PC board.• Hang the three mounting clips on the raised cab

Pagina 115

– 13 –2. If you want to connect the panel to phone lines that require ground startcapability, then a 675 Ground Start Module must be used. This module

Pagina 116

–14– NO CONNECTIONTRANSFORMER16.5VAC, 40VAADEMCO No.1361(IN CANADAUSE No. 1361CN)or 4300 IF X-10 DEVICES WILL BE USEDConnect to24hr. 120VAC,60 Hz O

Pagina 117

– 15 –The complete wiring for the 4300 transformer is also covered in Section 9:RELAY OUTPUTS & POWERLINE CARRIER DEVICES.Installing The Back-Up B

Pagina 118

–16–Section 4: THE MECHANICS OF PROGRAMMINGThis section provides the following information:• Using Data Field Program Mode• System and communication

Pagina 119 -

– 17 –2. After entry into the program mode, the following will be displayed:Program Mode*Fill # View -003. Following this display, enter * and the fir

Pagina 120

– i –TABLE OF CONTENTSHOW TO USE THIS MANUAL ... viiCONVENTIONS USED IN THIS MANUAL...

Pagina 121 - ZONE TYPE DEFINITIONS

–18–Programming System-Wide Data FieldsValues for some programming fields are system-wide (global), and some can bedifferent for each partition (parti

Pagina 122 - ∗) to exit back to normal

– 19 –#93 Menu Mode ProgrammingThe #93 Menu Mode is a mode through which much of the system'sprogramming is done. It offers main menu selections

Pagina 123

–20–Section 5: INSTALLING THE KEYPADSThis section provides the following information:• A list of wired keypads that may be used• Instructions for w

Pagina 124

– 21 –4. Connect keypads to the Keypad Port terminals 6, 7, 8, and 9 on the controlboard, as shown in Figure 4.KEYPADSBLACKREDGREENYELLOWCONTROLTERMIN

Pagina 125

–22–SUPPLEMENTARYPOWER SUPPLY+–CONTROLTERMINAL STRIPAUX AUX.DATA DATA + – IN OUT6789IMPORTANT:MAKE THESECONNECTIONSDIRECTLY TOSCREWTERMINALS ASSHOWN.T

Pagina 126

– 23 –4. After addresses are set, the green “READY” LED (or “POWER” LED on sometypes of keypads) should light, and the word READY (Fixed-word keypads)

Pagina 127

–24–SOUND OPTIONKeypads can be individually programmed to suppressarm/disarm beeps, entry/exit beeps and chime modebeeps. This helps prevent unwanted

Pagina 128

– 25 –Section 6: BASIC HARDWIRED ZONES 1-9This section provides the following information:• Common characteristics of hardwired zones• Wiring burglar

Pagina 129 - CHARACTER (ASCII) CHART

–26–UL1. A zone must be EOLR supervised when used for fire or burglary in UL Listed Commercial Burglary installations.2. Zone 9 is unsupervised and ma

Pagina 130

– 27 –Compatible 2-Wire Smoke DetectorsYou may use up to sixteen 2-wire smoke detectors each on zone 1listed in thetable below.DETECTOR TYPE DEVICE M

Pagina 131 - to exit Menu Mode

–ii–Section 6: BASIC HARDWIRED ZONES 1-9 ... 25Common Characteristics of Hardwired Zones ...

Pagina 132 - * to accept entry

–28–ULPower to 4-wire smoke detectors must be supervised (use a System Sensor A77-716-01 EOL relay module connected as shown).4-WIRESMOKEDETECTOREOLRE

Pagina 133

– 29 –Configuring Zone 7 for Alternate Keyswitch FunctionZone 7 may be programmed to serve as a keyswitch input. If using a keyswitch,it can be assig

Pagina 134

–30–Compatible Glass Break DetectorsUse detectors that meet the following ratings:Standby Voltage: 5VDC–13.8VDCStandby Resistance: Greater than 20k oh

Pagina 135

– 31 –ZONE PROG?1=YES 0=NOPress 1 to enter ZONE PROGRAMMING mode.While in this mode, press * to display the nextscreen, or press # to display th

Pagina 136

–32–02 Input TypeHardwired 1:1:Enter the input device type as follows:0 = not used; 1=hardwiredPress * to continue.The summary screen i

Pagina 137

– 33 –Section 7: 2-WIRE POLLING LOOP ZONES 10 - 86This section provides the following information:• Polling loop overview• Common characteristics of

Pagina 138

–34–When running polling loop wires, they must be at least 6" away from A.C. voltage,telephone, or intercom wiring. Since the polling loop is ca

Pagina 139

– 35 –The 4197 Polling Loop Extender Module may be used to provide additionalpolling loop current, to extend the polling loop wire run, and/or to prov

Pagina 140 - Number (HH:MM) (HH:MM)

–36–Programming Polling Loop Zones1. With at least one two-line alpha keypad (5137AD/6139) wired and set to aproper address, power up the system tempo

Pagina 141

– 37 –10 Input TypeEnter the input device type as follows:6=serial number polling loop device (SL type); 7=DIPswitch type (left loop) polling loop de

Pagina 142

– iii –Section 10: 4285 VISTA INTERACTIVE PHONE (VIP) MODULE ... 65General Information ...

Pagina 143 - HOLIDAY NUMBER ?

–38–Check-Out Procedure For Polling Loop ZonesAfter installation of all polling loop zones is complete, each partition of thesecurity system should be

Pagina 144

– 39 –Compatible Polling Loop Devices4208 8-Zone Expander • Accommodates up to 8 zones via the polling loop.• DIP switch programmable.• The first two

Pagina 145

–40–Compatible Polling Loop Devices4197 Extender Module • Used to increase the polling loop current (64mA), to extend the polling loop wire run length

Pagina 146 - 01 RELAY GRP # ?

– 41 –Section 8: WIRELESS (RF) ZONE EXPANSIONThis section provides the following information:• Common characteristics of wireless zones• Wireless sy

Pagina 147 - GROUP ? 12345678

–42–Wireless System Operation and Supervision• The receiver responds to status and alarm signals from wireless transmitters(@ 345MHz USA; 315MHz (5700

Pagina 148 - MON A1 Window 2 ?

– 43 –Installation and Setup of the 4281/5881 Wireless Receivers1. Mount the receiver(s). Receivers must be mounted externally to the controland can

Pagina 149

–44–Installing the 5800TM ModuleInstallation of this module is necessary only if you are using one or more 5827BDWireless Bi-directional keypads.The 5

Pagina 150

– 45 –The system House ID and the Device Address of the receiver are two differentthings. The House ID allows the system to identify transmitters wit

Pagina 151 - 06 ENTER OUTPUT#

–46–5700 Series Transmitter SetupEach 5700 series transmitter has DIP switches to set both the transmitter's zonenumber (Transmitter ID) and the

Pagina 152 - 06 Days? MTWTFSS

– 47 –Wireless Zone Assignments for 5700 Series TransmittersEach wireless zone can be assigned any zone response type, such as Entry/Exit,Interior Fol

Pagina 153

–iv–Section 17: ZONE TYPE DEFINITIONS... 92Section 18: DATA FIELD DESCRIPTIONS...

Pagina 154 - ], or [A] = 95;Duress = 92

–48–Compatible 5700 Series TransmittersModel Product Zone Num. Description5701 Panic Transmitter 62 or 63 • Programmable for either silent or audible

Pagina 155

– 49 –5800 Series Transmitter Setup5800 series transmitters have built-in serial numbers that must be "learned" bythe system using the # 93

Pagina 156

–50–• Button type transmitters (ex. 5801, 5802, 5802CP & 5803) should beperiodically tested by the user for battery life.Do not install batteries

Pagina 157 - NOTES Note: Low Speed will

– 51 –Model Product Learn As DescriptionInput Type5816 Door/Window RF • Has two unique input (loop) codes:Transmitter: one for a wired closed circuit

Pagina 158

–52–Programming Wireless TransmittersZone number assignments can be from 01-63 for 5700 series transmitters, and01-86 for 5800 series transmitters, ex

Pagina 159

– 53 –10 Zone TypeZone disabled 00Refer to the ZONETYPE DEFINITIONSsection for definitions ofeach zone type.Each zone in a system must be assigned a

Pagina 160

–54–10 INPUT S/N :L A000-0000:1If learning the serial number now (entering 1 at thelast prompt), this prompt appears. Fault the andrestore t

Pagina 161

– 55 –Check-Out Procedure for Wireless ZonesGo/No Go Test ModeBefore mounting transmitters permanently, conduct Go/No Go tests to verifyadequate signa

Pagina 162 - Other brands are not

–56–Section 9: RELAY OUTPUTS &POWER LINE CARRIER (X-10) DEVICESThis section provides the following information:• Output Device Basics• Wiring the

Pagina 163

– 57 –SWITCH 4 2 0 4 A D D R ESS SETTINGSPOSITION ("—" means "OFF")0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 152ON — ON — ON — ON — ON —

Pagina 164

– v –Section 24: SECURITY ACCESS CODES ... 155General Information ...

Pagina 165 - LOG PRINTER CONNECTIONS

–58–Programming the Relay Module1. With at least one alpha keypad (5137AD/6139 wired and set to a properaddress, temporarily power up the system by pl

Pagina 166

– 59 –1) a. EVENT (EV) is the condition (Alarm, Fault, Trouble) that mustoccur to a zone or group of zones (zone list) in order toactivate the device.

Pagina 167 - Auth Title

–60–STOP (STP):The "STOP" programming determines when and under whatconditions the device will be de-activated. The followingoptions are ava

Pagina 168

– 61 –01 Start EventNot usedA relay may be activated either by an Event used inconjunction with a Zone List, or by a ZoneType/System Operation. If

Pagina 169

–62–Relay GroupRelays may be grouped for common activation bytime driven events (commands 06-10--see Section20: SCHEDULING OPTIONS for more informatio

Pagina 170

– 63 –Zone List ProgrammingAfter all relays have been programmed, upon entering 00 at the "ENTER RELAYNO." prompt, you will be asked to ente

Pagina 171

–64–ENTER RELAY NO.00=QUIT 01Enter the 2-digit relay/X-10 module number (01-16)for the relay desired, or enter 00 to quit relay voicedescri

Pagina 172

– 65 –Section 10: 4285 VISTA INTERACTIVE PHONE(VIP) MODULEThis section provides the following information:• General information about the 4285 VIP mo

Pagina 173 - Section 25: KEYPAD FUNCTIONS

–66–Do not mount the VIP Module on the cabinet door or attempt to attach it to thePC board.2. When mounting the VIP Module outside the cabinet, use th

Pagina 174

– 67 –4285 WIRING NOTES:1. Wire the 4285 VIP Module exactly as shown, using a direct-connect cord and RJ31X jack.2. If Touch-tones are not present fol

Pagina 175

–vi–LIST OF FIGURES1. Installing The Lock ... 102. Cabinet Attack Resistance Co

Pagina 176

–68–3. From data field programming mode, press #93 to display the "ZONEPROG?" prompt. Press 0 to each menu option until "DEVICE PROG?&q

Pagina 177 - ENTER DEVICE NO

– 69 – Section 11.AUDIO ALARM VERIFICATION (AAV) UNITThis section provides the following information:• General information about the AAV option• AAV

Pagina 178

– 70 –Some AAV modules allow remote triggering by ring detection at the alarminstallation. Please be advised that if this option is selected, it may

Pagina 179

– 71 –1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16▲ONMODEL EAGLE SECURITY1241REFER TO AAV MODULEINSTRUCTIONS FOR CONNECTIONSTO AUDIO SPEAKERSAND MICR

Pagina 180

– 72 –Section 12: VOLTAGE TRIGGERS (Connector J7)This section provides the following information:• General information about the voltage triggers• Gr

Pagina 181

– 73 –1 2 3 4 5 6 7 8 9GRAYYELLOWWHITEREDGREENBROWNBLUEBLACKGROUNDOUT 1GROUNDOUT 2GROUNDOUT 3GROUNDOUT 4J7 CONNECTOROUT 1: GROUND START OR OPEN/CLOS

Pagina 182 - REGULATORY AGENCY STATEMENTS

– 74 –Ground Start Trigger SetupULNot intended for use in UL Listed applications..Output 1 may be used to trigger an optional 675 Ground Start module

Pagina 183

– 75 –Open/Close Trigger SetupOutput 1 may alternately be programmed to change states when the system isarmed in the away mode and then disarmed. If

Pagina 184

– 76 –Programming Remote Keypad Sounding Options1. With at least one two-line alpha keypad (5137AD/6139) wired and set to aproper address, power up th

Pagina 185

– 77 –NOTE:The tamper switch need not beused for UL Household Fire orBurglary installations. The tamper switch must be connected to an EOLRsupervised

Pagina 186

– vii –HOW TO USE THIS MANUALThis manual is written to accommodate both the new and the experienced installer ofAdemco products. A general descriptio

Pagina 187

– 78 –Auxiliary Alarm Signaling Equipment (Long Range Radio)The J7 header provides triggers for fire alarm, burglary/audible panic alarm,silent/duress

Pagina 188 - BATTERY REMOVED

– 79 –Section 13. EXTERNAL SOUNDERSThis section provides the following information:• General information about external sounders• Connecting external

Pagina 189 - SUMMARY OF SYSTEM COMMANDS

– 80 –UL1023 Household & UL609 Commercial Burglary InstallationsFor installations which must provide only UL Listed burglary protection, the total

Pagina 190 - SPECIFICATIONS

– 81 –Compatible SoundersULUse only UL Listed sounding devices for UL installations.702 Outdoor Siren Self-contained siren (driver built-in) and(not U

Pagina 191 - CONTACTING TECHNICAL SUPPORT

– 82 –Section 14: EVENT LOG OPTIONSThis section provides the following information:• General information about the Event Log• Event Log printer connec

Pagina 192

– 83 –1. Printer must be configured as follows:• 8 data bits, no parity, 1 stop bit• 300 or 1200 baud (1200 preferred)• Hardware handshaking using DTR

Pagina 193

– 84 –Display/Printing: After entering either the Display or Print mode, the followingwill be displayed:ENTER 0 = RECENT1 = COMPLETEThe Event Log hold

Pagina 194 - WARNING!

– 85 –CLEAR EVENT LOG0=NO 1=YESPress [1] if Event Log is to be cleared from memory.All events in the log will still be displayed if theCOMPLETE optio

Pagina 195 - N5945-6V2 2/98

– 86 –Section 15: FINAL POWER-UP PROCEDUREThis section provides the following information:• Earth ground considerations• Connecting the AC transforme

Pagina 196 - N5944-6V1 Rev B 4/99

– 87 – NO CONNECTIONTRANSFORMER16.5VAC, 40VAADEMCO No.1361(IN CANADAUSE No. 1361CN)or 4300 IF X-10 DEVICES WILL BE USEDConnect to24hr. 120VAC,60 Hz