– 31 –
Security Codes & Authority Levels
Security Codes & Authority Levels Security Codes & Authority Levels
Security Codes & Authority Levels
(Cont.)
(Cont.)(Cont.)
(Cont.)
How to Assign
How to Assign How to Assign
How to Assign Security
Security Security
Security Codes and Attributes
Codes and AttributesCodes and Attributes
Codes and Attributes
The following lists the command strings for adding user codes and attributes.
Refer to the User Setup chart at the back of this manual for factory
assignments of user attributes and to keep a record of user programming.
Change System
System Master code + [8] + 02 + new Master code + new code again
Master Code The System Master code can be changed only by using the current
System Master code or by the Installer using the Installer code.
Add a User: System Master code + [8] + user no. + new user’s security code
User 01 = installer User 03-17 = standard users
User 02 = master (factory set master code is 1234)
The Keypad beeps once to confirm that new user was added.
Delete a User: System Master code + [8] + [user no.] + [#] [0]
The security code and all attributes set for this user number,
including any associated RF keys, are erased from the system.
Authority Level: System Master code + [8] + [user no.] + [#] [1]+ auth. level
Factory Assignments: Authority Levels (see definitions on previous page):
users 03-16 = 0 0 = standard user 2 = guest
1 = arm only 3 = duress
Access Group: System Master Code + [8] + [user no.] + [#] [2]+ group (1-8)
Factory Assignments: none You can assign users to a group, then set an access schedule that
defines the times this group of users can operate the system. The
system ignores these users outside the scheduled times.
RF Zone Number: System Master Code + [8] + [user no.] + [#] [4]+ zone no.
(adding a Key Fob) Use this command to assign a wireless button device (key fob) to a
user for arming/disarming functions (key fob must be enrolled in
system first; see your installer).
Factory Assignments: none Zone number: enter the zone number assigned to a button on the
key fob that will be used for arming/disarming by this user.
Deactivating a key fob: You can deactivate the arming/
disarming functions for a key fob (ex. if lost or stolen) by deleting
the associated key fob user. See “Delete a User” above. Other key
fob functions such as panic or device activation (if programmed)
remain active. To fully remove the programming for a key fob, see
your installer.
Pager On/Off: System Master Code + [8] + [user no.] + [#] [5] + 0 or 1
Factory Assignments: You can program a user so that a message is sent to a pager
users 01-16 = 1 (on) whenever this code is used to arm or disarm the system.
Paging On/Off: 1 = allow paging; 0 = no paging for this user
Comentarios a estos manuales