-6-
–––––––––––––––––––––––––– COMPATIBLE DEVICES –––––––––––––––––––––––––––
Remote Keypads (up to 4)
Model Type
4127, 6127 Fixed English
4137AD, 6137, 6128 Fixed English Addressable
5330 (Select for Vista) Alpha
IMPORTANT
Addressable keypads must be used in
the non-addressable mode (Device
Address 31), which is pre-set at the
factory. Do not set these keypads to
any other addresses.
Smoke Detectors (4-wire only)
Model Type
1412 Ionization Products of Combustion
Detector
2412 Photoelectric Smoke Detector
2412TH Photoelectric Smoke Detector)w/135º F
(57º C) Heat Detector)
Fire Supervisory Module
A77-71601 EOL Relay Module (supervises power
for 4-wire fire zone).
5700 Series Transmitters
Model Description Zone Num.
5701 Panic Transmitter 62 or 63
5706 Photoelectric Smoke 48-55
5707 Detectors
5711 Slimline Door/ 1-63
Window Transmitter
5715WH Universal Transmitter 1-63
5716 Door/Window 1-63
5716WM Transmitter
5742 Audio Discriminator 1-63
5743 Dual Technology 1-63
Glassbreak Detector
5775 PIR Detector 32-47
5727 Wireless Keypad House ID
5827BD Wireless Bi-directional House ID
Keypad
5799 Magnets
U
L
The 5711, 5715, and 5716 do not supervise
their loop wiring. Therefore, their loop
wiring may not exceed three feet.
Optional Keyswitch
4116 Keyswitch
––––––––––––––––– ZONE RESPONSE TYPE CHARACTERISTICS –––––––––––––––––
Zone Response Type Characteristics
0 – Zone Disabled
1 – Entry/Exit Burglary • Provides exit delay time when panel is armed in any arming mode.
• Provides entry delay when panel is armed in Away and Stay modes
only.
3 – Perimeter Burglary • Provides an instant alarm when panel is armed in any arming mode.
4 – Interior, Follower • Provides exit delay time when panel is armed in any mode.
• Will only provide entry delay if an Entry/Exit zone is faulted first upon
entry. Otherwise, alarm will be instant.
• Bypassed automatically when panel is armed in the Stay or Instant
mode.
5 – Trouble by Day/Alarm by
Night
• Provides a trouble response if panel is not armed when zone is faulted.
• Provides an instant alarm if panel is armed in any mode.
6 – 24-Hr. Silent Alarm • Provides a silent alarm to Central Station whether panel is armed or
disarmed.
7 – 24 Hr. Audible Alarm • Provides an audible alarm at the bell output and keypad whether panel
is armed or disarmed.
8 – 24-Hr. Auxiliary Alarm • Provides an audible alarm at the keypad only. No bell output is
provided.
9 – Fire • Provides a fire alarm when zone is shorted. Causes bell output to pulse.
• Provides a trouble response when zone is open.
10 – Interior w/Delay • Provides entry and exit delay times.
• Bypassed automatically when panel is armed in the Stay or Instant
mode.