1-1
SECTION 1
General Description
••••••••••••••••••••••••••••••••••••••••••••••••
About the VISTA-32FB
The VISTA-32FB is a two-partition, UL Listed Commercial Fire and Burglary control panel. The Control can also be
used as a slave communicator in conjunction with an external fire alarm panel: For use as a slave communicator, refer
to Section 11 of this manual. Unless otherwise indicated, all other information in this manual describes the control
panel as a Commercial Fire/Burglary detection system.
Features
Hardwire and Optional Expansion Zones
Provides eight hardwire zones.
Supports up to 16 2-wire smoke detectors each on zone 1 and zone 2 (32 total).
Triggers the built-in sounders on other hardwired smoke detectors if one smoke detector annunciates an alarm.
Supports up to 50 2-wire latching glassbreak detectors on zone 8.
Supports up to 24 additional expansion zones using a built-in polling (multiplex) loop.
Supports up to 32 wireless zones fewer if using hardwire and/or polling loop zones.
Provides three keypad panic keys: 1 + (A), + # (B), and 3 + # (C).
Peripherals Devices
Supports up to 31 addressable devices, (keypads, RF receivers, relay modules, etc.).
Supervises devices (keypads, RF receivers, and relay modules) and individual relays (up to 32), as well as system
zones (RF receivers and keypad panics).
Provides 96 outputs using 4204 and 4204CF Relay Modules, and V-Plex Relay Modules can activate outputs in
response to system events (alarm condition), at a specific time of day, at random times, and manually using the #70
Relay Command Mode.
Supports one additional style-Y supervised Notification Appliance Circuits using a 4204CF.
Supports the ADEMCO 4146 Keyswitch on either of the system's two partitions.
Arming/Disarming and Bypassing
Provides global arming capability (ability to arm all partitions the user code has access to in one command).
Supports Exit Error Logic, whereby the system can tell the difference between a regular alarm and an alarm caused
by leaving an entry/exit door open. If the system is not subsequently disarmed, faulted entry/exit zone(s) and/or
interior zones are bypassed and the system arms.
Supports Recent Close report, which is designed to notify the central station that an alarm has occurred within 2
minutes after the exit delay has expired.
Partitioning
Can control two separate areas (partitions) independently, each functioning as if it had its own separate control. All
fire zones must be assigned to partition 1.
Provides a Common Lobby partition, which can be programmed to arm automatically when the other partition is
armed, and to disarm when the other partition is disarmed.
Provides a Master partition (3) used for the purpose of viewing the status of all partitions at the same time.
Can display fire, burglary, panic, and trouble conditions at all other partitions’ keypads (selectable option).
Scheduling
Can automate system functions, such as arming, disarming, and activation of outputs (e.g., lights).
Provides an End User Output Programming Mode, allowing the user to control outputs.