l = LOOP NUMBER
Used with 5800 RF Loop Input Devices. Record transmitter loop number.
Entries are 1-4, depending on device being used. Refer to the transmitter’s instructions for
appropriate loop numbers.
POWERLINE CARRIER DEVICES WORKSHEET FOR
*
80, and
*
81.
Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is used.
8
/
Powerline Carrier Devices and the PL513 Powerline Interface Module are not UL Listed for fire or burglar
functions and are intended for home automation.
✱
80 OUTPUT DEVICES
Fill in the required data on the worksheet on below and follow the programming procedure in the Installation Instructions as
you enter the data during the displays and prompts that appear in sequence.
Note:
Field
✱
25 must be programmed with a House Code.
START
either or both
STOP
either or both
DEVICE
NUMBER
ACTION
(aa)
EVENT ZONE
TYPE LIST
(et) (zl)
ZONE TYPE
SYST OP'N
(zt)
RESTORE
ZONE LIST
(zl)
ZONE TYPE
/SYST OP'N
(zt)
P.L.C.D.
*†
01
P.L.C.D.
*†
02
P.L.C.D.
*
†
03
P.L.C.D.
*
04
P.L.C.D.
*
†
05
P.L.C.D
.*
†
06
SYSTEM
07
*
SYSTEM
08
*
[2] [33] [36]
*
P.L.C.D. = Powerline Carrier Device (X-10).
Note:
If using an X-10 Powerhouse Security SH10A Siren as device 8, you must change the action default to “3” if using
default table 4.
Where:
A = DEVICE ACTION
0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
ET
= EVENT TYPE
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
Z L
= ZONE LIST
1, 2, or 3 (from Field
✱
81) or 0 = Not Used.
"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will START.
"STOP"
RESTORE
of
ZONE LIST: Upon restore of ALL zones on this list, device action will STOP.
It need not be same list as used for START.
NOTE:
Do not assign zones with zone types 20, 21, or 22 to a zone list.
ZT = ZONE TYPE/SYSTEM OPERATION Choices for Zone Types are:
00 = Not Used 06 = 24 Hr Silent
01 = Entry/Exit#1 07 = 24 Hr Audible
02 = Entry/Exit#2 08 = 24 Hr Aux
03 = Perimeter 09 = Fire Zone
04 = Interior Follower 10 = Interior w/Delay
05 = Trouble Day/Alarm Night 24= Silent Burglary
Note
:
Any
zone in "ZT" going into alarm,
fault, or trouble will activate device.
Any
zone of that type that restores
will stop device action.
Choices for System Operation are:
20 = Arming–Stay 38 = Chime
21 = Arming–Away 39 = Any Fire Alarm
22 = Disarming (Code + OFF) 40 = Bypassing
31 = End of Exit Time 42 = System Battery Low * Or at Disarming, whichever occurs
32 = Start of Entry Time 43 = Communication Failure earlier.
33 = Any Alarm (except ZT=08) 52 = Kissoff
36 = *At Bell Timeout 58 = Duress