- 10 -
-%
zt
STOP ZONE TYPE
(if applicable)
Enter the 2-digit stop zone type for the device being programmed ( see Powerline Carrier Device
Worksheet for zone type/system operation codes later in this manual).
[*] = Return to Device Number prompt (A)
[#] = Return to previous prompt
*81 ZONE LISTS
Use this mode to define zone lists for Powerline Carrier Devices and/or for the chime by zone feature. Press *81
while in programming mode.
NOTE:
Entry of a number other than one specified will give unpredictable results.
-
ZONE LIST PROGRAMMING
0 = Exit mode, upon which this prompt blinks. Press [*] + any field number to go to that field.
1 = Enter mode
%-
ZONE LIST NUMBER
Enter the 2-digit zone list number (01-03) to be programmed (use zone list 03 for chime by zone feature).
[*] = Continue
00 = Exit mode (displays blinking 81; enter * + desired data field or menu mode number)
b
zz
ZONE ENTRY TO LIST
Enter the 2-digit zone number (
zz
) to be added to this zone list.
[*] = Accept zone number and enter the next zone number
00 = Accept zone number and continue to next prompt
'
DELETE ENTIRE ZONE LIST?
0 = Don’t delete; continue to next prompt
1 = Delete the current zone list
d
DELETE SPECIFIC ZONES FROM LIST?
0 = Don’t delete; continue to next zone list number (prompt A 01)
1 = Continue to delete zones prompt
)
DELETE ZONES
Enter the 2-digit zone number to be deleted from the current zone list
[*] = Delete zone and enter next zone to be deleted
00 = Return to next zone list number (prompt A 01)
*83 ENHANCED SEQUENTIAL MODE
Use this mode to enter transmitter serial numbers. Press *83 while in programming mode.
NOTE:
Entry of a
number other than one specified will give unpredictable results.
%-
ZONE NUMBER
Enter the 2-digit zone number of the first transmitter to have its serial number entered.
[*] = Continue; system searches for zones not yet entered, (for zones 2 to 25 a zone type must be
entered) then advances to ENROLL SERIAL NUMBER prompt (1b).
00 = Exit Sequential mode, upon which the prompt “83” blinks. Press [*] + any field number to go to that
field.
-%
zz
-% 0'
ENROLL MODE
0 = Advance to next unlearned zone.
1 = Enter now and proceed to SERIAL NUMER prompt (1b). For 4-button keys (zones 26, 30, 34 and 38)
the serial number will be learned to all four buttons.
2 = Copy the last serial number entered. If this is the first zone, no serial number will be in the buffer and
the panel will emit a long tone.
3 = View existing serial number. (Only if “L” is displayed. If “L” is not displayed, panel will emit a long
beep. Each digit will be displayed and the keypad will beep once for digits 1-6 and three times for last
digit.
4 = Copy the 4-button key template set for zones 26 - 29 (includes all zone parameters except serial
numbers). Only valid on 4-button key zones 30, 34 and 38 that do not have serial numbers learned.
(Template acceptance is indicated by two beeps after copying. A single long beep emitted when copying
templates indicates the template is not valid.)
9 = Delete existing serial number. Go to the (1A) prompt. (For 4-button key zones 26, 30, 34 and 38,
deletes all four at once.)
[*] = Advance to the next unlearned zone.
[#] = Return to previous prompt (1A).