POWERLINE CARRIER DEVICES WORKSHEET FOR
80, and
81.
Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is used.
U
L
Powerline Carrier Devices have not been evaluated by UL.
80
OUTPUT DEVICES
Fill in the required data on the worksheet on below and follow the programming procedure in the Installation
Instructions as you enter the data during the displays and prompts that appear in sequence.
Note: Field
25 must be programmed with a House Code.
START
either or both
STOP
either or both
DEVICE
NUMBER
ACTION
(aa)
EVENT ZONE
TYPE (et) LIST (zl)
ZONE TYPE
SYS OPERATION (zt)
RESTORE
ZONE LIST (zl)
ZONE TYPE/
SYS OPERATION (zt)
P.L.C.D.*† 01
P.L.C.D.*† 02
P.L.C.D.* 03
P.L.C.D.* 04
P.L.C.D.* 05
P.L.C.D.* 06
SYS. P.L.C.D.* 07
SYS. P.L.C.D.* 08 [2] [33] [36]
* P.L.C.D. = Powerline Carrier Device (X10).
Note: If using an X10 Powerhouse Security SH10A Siren as device 8, you must change the action default to “3” if using default table 4.
Where: A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
ET = EVENT TYPE 0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
Z L = ZONE LIST 1, 2, or 3 (from Field
81) or 0 = Not Used.
"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will
START. "STOP" RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action
will STOP. It need not be same list as used for START.
Note: Do not assign zones with types 20, 21, or 22 to a zone list.
ZT = ZONE TYPE/
SYSTEM OPERATION
Choices for Zone Types are:
00 = Not Used 04 = Interior Follower 08 = 24 Hr Aux
01 = Entry/Exit#1 05 = Trouble Day/Alarm Night 09 = Fire Zone
02 = Entry/Exit#2 06 = 24 Hr Silent 10 = Interior w/Delay
03 = Perimeter 07 = 24 Hr Audible 24= Silent Burglary
Choices for System Operation are:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + FF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Alarm (except
ZT=08 or 09)
36 = *At Bell Timeout
38 = Chime
39 = Any Fire Alarm
40 = Bypassing 42 = System
Battery Low
43 = Communication Failure
52 = Kissoff
58 = Duress
* Or at Disarming, whichever occurs earlier.
Note: In normal operation mode:
For Devices 1-6: For Devices 7 and 8: N = device (unit)
number
Function + Lights On + N Code + Function + 4 + N (Entry starts Device N)
Function + Lights Off + N Code + Function + 7 + N (Entry stops Device N)
Note: Any zone in "ZT" going into alarm, fault, or trouble will activate
device with the exception of 01, 02 when the system is in
alarm. Any zone that restores will stop device action.