NIGHT SET
Night Set permits the user to set the system in selected areas, whilst others are unset,
e.g. unset in bedrooms whilst set in remaining rooms of house. This permits
freedom of movement in the secure environment.
To NIGHT SET the system:
1. Enter the User Code.
2. Press 3/ (NIGHT SET).
During the exit period, the DAY LCD symbol will flash. Two confirmation
beeps indicate that the system has set.
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 3/ (Night Set) to EASY SET the system, if available.
Unsetting the System
To UNSET the system:
1. Proceed to a keypad via the approved route and enter the User Code.
Resetting the System
To UNSET and RESET the system during or after an alarm:
Entering a User Code will stop any alarm in progress. The zone number causing the
initial alarm will then be displayed on the LCD keypad. The User Code may be
entered again to RESET the system.
If the panel has been programmed to accept only an Engineer Reset after an alarm
an Engineer Code is required to RESET the system.
If the panel has been programmed to accept only a Technistore Reset the keypad
will flash the cE symbol followed by the activated zone number. The cE symbol
will then flash again followed by a five digit code which should be given to the
monitoring station who will then issue an anticode. This anticode will RESET the
system when entered on the keypad.
8
Testing the System
To TEST the system:
1. Enter the User Code.
2. Press 5/ (TEST).
The outside bell/sounder will ring for 5 seconds and the strobe will flash until the
test is finished. The keypad LCD scrolls through zone numbers 1-8 for 5 seconds.
Note: Test each zone individually when the keypad stops scrolling and the
bell/sounder stops ringing. Activate the zone to verify display of zone on
the LCD, two beeps will sound. To exit test mode enter the User Code and
wait for two beeps.
Omitting Zones
To OMIT Zones:
1. Enter the user code.
2. Press 6/ (OMIT).
3. Enter the Zone Number(s) to be omitted.
4. Press Ö to finish or wait 5 seconds for confirmation beep.
5. Set the system
e.g. To omit zones 6, 7 and 8, press 1234 6/ 678. Zone No. 6, 7 and 8 will
flash. Press Ö or wait 5 seconds for confirmation.
To correct a wrong omitted zone:
1. Enter the User Code
2. Press 6/ (Omit)
3. Press Ö or wait for a confirmation beep.
Note: Fire, Silent PA and PA cannot be omitted.
Unsetting the system, will restore normal operation and all zones.