12
13
or not).
In addition, the system is placed in a test mode
(if the system is disarmed and no memory of alarm is present)
in which activation of
any
zone causes a brief l/2 second
sounding from the exterior alarm sounder(s), as.we1.l as
visual zone annunciation on the console's zone identification
display and on the appropriate C-COM zone LED (all but
zone 5). If the lest Mode is not manually terminated,
the system will automatically come out of the Test Mode
after 30 minutes.
tlot
IJssd
Am/Disam Input
(Momentary'HI to ARM or DISARM): This
input is normally provided by remote key arming stations
(e.g. t&s. 9787, 9789) for the purpose of arming or disarming
the system.
If the zone status indicates an open zone
and arming is desired in spite of the open zone, maintaining
this input HI for 5 seconds causes forced arming of the
system (automatic shunting of the open zone).
Once the system is disarmed, the silencing of any remaining
trouble or alan memory sound is accomplished by reactivating
this HI input. As long as conditions remain that need
to be cleared, activation of a key arming station cannot
rearm the system, only reset the interior audible annuncia-
tions.
Up to four arming stations can be supported by
the system.
lB2
Tcralnal s
1.3
2
4,5
6,7 ZONE
1
7,8 ZOM 2
9,lO ZOM 3
Incming Teko
Line Pair:
Connect T82-1 to the GREEN lead and TB2-3 to the RED lead on
the No. 620 RJ31X Direct Connect Cord. Do su& camat the latter
cord
to the
RJ31X
jack
until all wiring in the system has been
completed.
Cabinet Gromd (-):
Connect this terminal to a, good earth ground
(cold water pipe or electrical box ground is frequently satisfactory
for this usage,
but in some local
es is
not).
This connection
Is critlcal
to enhancing the immunity of the system to unwanted
induced voltages.
Internal Handsets:
Connect TB2-4 to the BROGlN lead and TB2-5
to the GRAY lead on the (JD. 620 RJ31X Direct Connect Cord.
Burg1 ary Protecti 8n Zones :
For each zone, run a pair of wires
from that zone's terminals to all protection points in the zone
and .terminate with a
1000
ohm End-of-Line Resistor (supplied)..
Each loop has normal (250 msec)
response
to open and closed
circuit devices such as mats, magnetic contacts, foil, etc.
Zones 2 and 3 are PROM progranmnable for
fast response (15
msec)
to quick acting devices such as vibration contacts and photoelectric
units without built-in delay.
628-37
714