-6-
Section 1. GENERAL DESCRIPTION
The 4110DL is a microprocessor-based state-of-the-art security controls intended for wired applications. The
Control Panel supports up to 6 hardwired zones and can be programmed either through the keypad or
remotely using ADEMCO's V-LINK downloading software.
––––––––––––––––––––––––––––––––––– FEATURES ––––––––––––––––––––––––––––––––––––
Zones Supported
• 6 hardwire zones, having the following
characteristics:
◊ EOLR supervision supporting N.O. or N.C.
sensors.
◊ 300-500 msec normal response.
◊ Zone 3 programmable for Fast Response to
open (10mS).
Security Codes
• 1 master code for entire system (user 1)
• 3 secondary user codes (users 2-4)
Keypad Panic Keys
• Provides 3 panic key functions
Alarm Output
• Provides a 12VDC, 2 AMP output (assumes a fully
charged battery is connected)
• Steady output for Burglary/Panic, or pulsing
output for Fire
• Output is current limited
Communication Formats
• Ademco Low Speed (Standard or Expanded):
1400Hz ACK/KISSOFF.
• Sescoa/Radionics (Standard or Expanded):
2300Hz ACK/KISSOFF.
• Ademco Express:
DTMF, 1400/2300Hz ACK, 1400Hz KISSOFF.
• Ademco Contact ID:
DTMF 1400/2300Hz ACK, 1400Hz KISSOFF.
––––––––––––––––––––––––––––––––
SPECIFICATIONS
––––––––––––––––––––––––––––––––
4110DL CONTROL
1. Physical:
12-1/2" W x 14-1/2" H x 3" D (318mm x 368mm x
76mm)
2. Electrical:
VOLTAGE INPUT: 16.5VAC from plug-in 25VA
transformer, Ademco No. 1321/TF2 (in U.S.A.),
1321CN (in Canada)
RECHARGEABLE BACK-UP BATTERY: 12VDC,
4AH (Gel type).
CHARGING VOLTAGE: 13.8VDC.
ALARM SOUNDER: 12V, 2.0 Amp output
AUXILIARY POWER OUTPUT: 12VDC, 500mA
max. Interrupts for 4-wire smoke detector reset.
MAXIMUM ZONE RESISTANCE: Zones 1-8 =
300 ohms excluding EOLR
U
L
In UL installations, maximum current
draw from the Auxiliary Output and
the Alarm Output combined must not
exceed 500mA total.
FUSE: Battery (3A) No. 90-12
LINE SEIZE: Double Pole
REGULATORY INFORMATION
Ringer Equivalence: 0.7B
FCC Registration No.: AC 398U-68192-AL-E
UL File No. S1632, Guide UXOU
––––––––––––––––––––––––––––– COMPATIBLE DEVICES ––––––––––––––––––––––––––––
Remote Keypads (up to 4)
Model Type
4127, 6127 Fixed English
4137AD, 6137, 6128 Fixed English Addressable
5330 (Select for Vista) Alpha
IMPORTANT
Addressable keypads must be used in
the non-addressable mode (Device
Address 31), which is pre-set at the
factory. Do not set these keypads to
any other addresses.
Smoke Detectors (4-wire only)
Model Type
1412 Ionization Products of Combustion
Detector
2412 Photoelectric Smoke Detector
2412TH Photoelectric Smoke Detector)w/135º F
(57º C) Heat Detector)
Fire Supervisory Module
A77-71601 EOL Relay Module (supervises power for 4-
wire fire zone).
Optional Keyswitch
4116 Keyswitch