SPECIAL MESSAGES
OC =
OPEN CIRCUIT (no communication between console and control).
EE
or
ENTRY ERROR
= ERROR (invalid field number entered; re-enter valid field number).
After powering up, "
AC, dI
"
(disabled) or "
Busy Standby
" and "
NOT READY
" will be displayed after approximately 4 seconds.
This will revert to
READY
in approximately. 1 minute, which allows PIRS, etc. to stabilize.
To bypass this delay, press: # + 0.
If
E4
or
E8
appears, more zones than the expansion units can handle have been programmed. Correct the programming and
then completely de-power and re-power the control to clear this indication and remove the disable indication.
TO ENTER PROGRAMMING MODE:
1.
POWER UP, then press
and
#
both at once, within 50 seconds of powering up.
OR
2.
Initially, key:
Installer Code
(
4 + 1 + 1 + 2)
plus
8 + 0 + 0.
OR
3.
If different
Installer Code
is programmed, key:
New Installer Code + 8 + 0 + 0.
(If
98 was used to exit previously, method 1 above must be used to enter the program mode again.)
TO EXIT PROGRAMMING MODE:
98
Exits programming mode and
prevents
re-entry by keying Installer Code + 8 + 0 + 0. If
98
is used to exit
programming mode, system must be powered down, and method 1 above used to enter the programming mode.
99
Exits programming mode and
allows
re-entry by keying Installer Code + 8 + 0 + 0; or by powering up, then pressing
and # within 50 seconds of power-up.