IX.
SPECIFICATIONS
4140XM CONTROL
Physlcal:
Width:
12 inches (305mm)
Height: 12 inches (305mm)
Depth:. 3 inches (76mm)
Electrlcal:
VOLTAGE INPUT: l&DC, 850 mA max. (from plug-
in Power Pack, Ademco No. 1360)
RECHARGEABLE BACK-UP BATTERY: 12VDC, 4 AH
Gel type)
ALARM SOUNDER OUTPUT: Wet contact relay (2.8A
max. contact rating @ 28VDC). Can drive 12V
motor driven bells (100 mA each) - AMSECO
MSBlOG or ABBlO31.
AUXILIARY POWER OUTPUT: 11.5 - 1AOVDC
700 mA for non-UL installations
400 mA max. for UL installations
STANDBY: 5.7 hours with Auxiliary load of 700
mA using 4 AH Battery. 8.5 hours with Auxiliary
load of 400 mA using 4 AH Battery
Fuses:
Battery Fuse: 3A Slo Blo (Ademco No. 90-28)
Auxiliary Power: 1A (Ademco No. 90-29)
Alarm Relay Power: 3A Sto Blo
(Ademco No. 90-28)
5130XM/4130XM CONTROLS
Physical:
Width: 8.4 inches (21.3cm)
Height: 4.75 inches (12.1 cm)
Depth: 1.1 inches (2.8 cm)
Electrlcaf:
VOLTAGE INPUT: 18VDC (from plug-in Power Pack,
Ademco No. 1350). 700 mA max.
RECHARGEABLE BACK-UP BATTERY: 12VDC, 1.2 AH,
Ademco No. 484 ‘(YUASA NP 1212). (Alternatively, a
4 AH Ademco No. 486 may be used’).
ALARM SOUNDER: Built-in piezoelectrfc sounder,
85 db at 10 feet. Sound produced is selectable as
“steady” (in compliance with UL 85 db output
requirement) or ‘sweeping’ (for non-UL usage).
Optional external 12V Piezoelectric alarm sounder
(100 mA max.). (Ademco No. ,740 or BRK PA4OOB).
Optional 12V motor-driven Bell (100 ma max.).
(AMSECO MSBlO-G or ABB-1031).
Optional dry contact relay (2.8A .max. contact rating
@28VDC). Ademco No. 4148’. Can drive No. 719 or No,
702 Siren.
AUXILIARY POWER OUTF’lJTz 10.2-13.8VDC
280 mA for non-UL installations
200 mA max. for UL installations
STANDBY: 2.5 Hours with 200 mA standby current
*
DIGITAL COMMUNICATION INTERFACE
load. 5 Hours with no external current load.
BOARD (4171XT-XM)
*Not available in a UL installation,
Physltal: 5-314” (14.6 cm) x 3-118’ (8.25
cm)
x 7/S” (2.2 cm) (approx.).
513714137 REMOTE CONSOLES
Functlonal:
FORMATS SUPPORTED:
ADEMCO LOW SPEED, 10 pulses/set. 1900 Hz
Data Tone, 1400 Hz ACKIKISSOFF.
SESCOA, 20 pulses/set, 1800 Hz Data Tone,
2300 Hz ACKIKISSOFF, Variable. Interdigit
Timing.
RADIONICS, 20 pufses/sec, 1800 Hz Data
Tone, 2300 Hz ACKIKISSOFF, Fixed Interdigit
Timing.
ADEMCO CONTACT ID
LINE SEIZE: Double Pole
RINGER EQUlVALENCE: O-78
FCC REGISTRATION NO.: AC 398U-68192-AL-E.
Physlcal:
Width: 8.4 inches (213 mm)
Height: 4.75 inches (121 mm)
Depth: 1 .l inches (28 mm)
Electrlcal:
Voltage Input: 12VDC
Current Drain:
60 mA (4137) continuous
90 mA (5137) with back lighting
Interface Wlrlng:
RED: 12VDC input (+) - auxiliary power
BLUE: 18VDC input (+) - from optional 1350 or
1360 Power Pack’
GREEN: Data In
YELLOW: DataOut
BLACK: Ground and (-) connection from
optional 1350 or 1360 Power Pack.
l
Not permitted for UL installations.
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital
to continuous satisfactory operation of any alarm system.
The installer should assume the responsibii of developing and .offering a regular maintenance program to the
user as well as acquainting the user with the proper operation and limitations of the alarm system and its
component parts. Recommendations must be included for a specific program of frequent testing (at least
weekly) to insure the system’s proper operation at all times.
- 17 -
WWW.DIYALARMFORUM.COM