- POWERING THE SYSTEM -
PRIMARY. POWER
Power to the 4140XM Control panel is supplied by a
Plug-In DC Power Pack, 1360, which is rated at
850 mA @ 18 volts DC. The 4130XM and 5130XM
Controls are supplied by a 1350 Plug-In DC Power
Pack rated at 700mA @18 volts DC. Since these
power packs supply unregulated DC, and because
they are polarized (+) & (-), caution must be taken
when wiring them to the Controls.
BACK-UP POWER
In the event of an AC power loss, all VISTA XM
Controls are supported by a back-up, rechargeable
gel cell battery.
BATTERY STANDBY TABLE
4130XM1513dXM 4140XM
AMP-HRS
200
mA
400
mA
700mA
1.2
3.0
hrs.
N/U
N/U
4.0
10.0 hrs.
10.0 hrs. 5.7 hrs.
6.0
15.0 hrs.
15.0 hrs. 8.5 hrs.
NOTE: The above figures are approximate, and
may vary depending upon the age. quality, and
capacity of the battery at the time of the AC loss.
TB2 TB2
CAlJlmN: ‘OssmvE POLARllv
’ g?----
llmmlmml
‘KEEP WIRE RUNS As SHORT AS POSSIBLE!
‘4.MW MINIMUM BATIERY CAPACITY
%oAn MAXIMUM SAlTERI WPAcrY
414OXY POWER
PACK
BAllZRY CONNECTIONS
POWER-UP PROCEDURE
1.
Wire the 1350 (1360) DC Power Pack first
(before the battery), making sure polarity is
correct and the terminal strip (or harness) is
connected to the Control panel as shown in the
SUMMARY OF CONNECTIONS diagrams. Do not plug
in at this time.
2. Connect all auxiliary devices, such as
consoles, PIRs, etc.
3. Plug the 1350 into an AC outlet. Check that the
Auxiliary Voltage measures between 13.5 and 14.0
volts DC. If under 13.5 volts, too much current is
being drawn from the Control. See the
SPECIFICATIONS section of the
Technical Reference
Manual
for the current draw of each device.
4. Connect the battery as shown in the SUMMARY
OF CONNECTIONS diagrams. Do not connect the
battery if Auxiliary Voltage is below 13.5 volts, as
this will prevent the battery from being fully
charged.
CAUTION:
If total current draw is above the
maximum auxiliary current available, a 1350
power pack’ must be used to power up to 7
additional remote consoles. If only one console is
being used, power additional devices from a
separate 12VDC power source (i.e. 488-12).