Page 7
SUMMARY OF PROGRAMMING COMMANDS
• To enter program mode, enter installer code + [8] + [0] + [0]
• To set standard defaults, press *97
• To set communication defaults, press *94 + one of the following: *80=low speed; *81=Ademco Express;
*82=Ademco High Speed; *83=Ademco's Contact ID
• To change to next page of program fields, press *94
• To return to previous set of fields, press *99
• To erase account & phone number field entries, press [*] + field number + [*]
• To assign zone descriptors, press #93 + follow menu prompts
• To add custom words, press #93 + follow menu prompts
• To enter Installer's Message, press #93 + follow menu prompts
• To exit program mode, press *99 OR *98: *99 allows re-access to programming mode by installer code. *98 prevents
re-access to programming mode by installer code.
PROGRAMMING WITH #93 MENU MODE
Refer to the #93 Menu Mode section of the separate INSTALLATION INSTRCUTIONS/ PROGRAMMING GUIDE document for
detailed procedures.
After programming all system related programming fields in the usual way, press #93 while still in programming mode to display
the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu
selection. Pressing 0 will display the next choice in sequence. Menu selections are as follows:
ZONE PROG?
0=No 1=Yes
For programming the following:
• Zone Number
• Zone Response Type
• Hardwired zone
• Wireless Zone (type RF, UR or BR)
• Right/left Loop Zone
• Serial number RPM zone
• Partition Number for Zone
• Dialer report code for zone
SERIAL PROG?
0=no 1=yes
For entering (learning) 5800 transmitter & serial number polling loop device serial numbers into the
system.
ALPHA PROG?
0=no 1=yes
For entering alpha descriptors for the following:
• Zone Descriptors
• Installer's Message
• Custom Words
• Partition Descriptors
• Relay Descriptors
DEVICE PROG?
0=no 1=yes
For defining the following device characteristics for addressable devices, including consoles, RF
receivers (4281/5881) and 4204 output relay modules:
• Device Address
• Device Type
• Device's Home Partition
• Keypad Options
• Phone Module
RELAY PROG?
0=no 1=yes
For defining output relay functions.
RLY VOICE DESCR?
0=no 1=yes
For entering alpha descriptors to be used with phone module functions.
CUSTOM INDEX #?
0=no 1=yes
For creating custom word substitutes for voice module annunciation.
#93 MENU MODE KEY COMMANDS
The following is a list of commands used while in the menu mode.
#93 Enters Menu mode
[✱] Serves as ENTER key. Press to have keypad accept entry.
[#] Backs up to previous screen.
0 Press to answer NO
1 Press to answer YES
01-99 All data entries are 2-digit entries.
00 Escapes from menu mode, back into field programming mode.