ADEMCO 4110XM Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
- 5 -
Field Function Programmed Value [ ] = Default Value
*49 SPLIT/DUAL REPORTING
[0]
TO PRIMARY PHONE No. TO SECONDARY PHONE No.
0 = All Backup Report Only
1 = Alarms, Restore, Cancel Other Reports
2 = All Reports except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All Reports
4 = All Reports except Open, Close, Test All Reports
5 = All Reports (Dual Reporting)All Reports
TO PRIMARY PHONE No. TO PAGER No.
††
(secondary)
6 = All reports except open/close Alarms, Open/Close, Trouble
7 = All reports Alarms, Troubles
8 = All reports Alarms, Open/Close, Troubles
†† Can only be used if primary reporting format is ADEMCO Contact ID.
ALARM REPORT CODES (*50-*59)
*50 1st DIGIT OF Zn 95, Zn 96
(Keypad Panics) (95) (96)
Enter 1-9, 0, B-F as described in box below.
An entry of "0" will disable report.
2nd Digit of each (for expanded or 4+2 reporting) is same as for field *57.
Zone 95 is Console Silent Panic (Key A or 1 & 6).
Zone 96 is Console Audible Panic (Key C or 3 & #).
*51 ZONE 1 ALARM REPORT CODE
*52 ZONE 2 ALARM REPORT CODE
*53 ZONE 3 ALARM REPORT CODE
*54 ZONE 4 ALARM REPORT CODE
*55 ZONE 5 ALARM REPORT CODE
*56 ZONE 6 ALARM REPORT CODE
*57 ZONE 7 ALARM REPORT CODE
(Console Panic: Key B or *&#)
*58 ZONE 8 ALARM RPT CODE (Duress)
*59 NOT USED (Must be set to “00”)
SYSTEM STATUS REPORT CODES (*60-*68)
*60 TROUBLE REPORT CODE
*61 BYPASS REPORT CODE
*62 AC LOSS REPORT CODE
*63 LOW BAT REPORT CODE
*64 TEST REPORT CODE
*65 OPEN REPORT CODE
††
*66 CLOSE REPORT CODE
††
††
2nd digit is automatically sent as the user number if expanded or 4+2
reporting is selected.
TO PROGRAM REPORT CODES FOR ALARM, SYSTEM
STATUS, RESTORE (*51–*75)
For 3+1 or 4+1 Standard Format:
Enter a code in the first box: 1-9, 0, B, C, D, E, or F. Enter
"#+10" for 0, "#+11" for B, "#+12" for C, "#+13" for D,
"#+14" for E, "#+15" for F.
For Expanded or 4+2 Format:
Enter codes in both boxes (1st and 2nd digits) for 1-9, 0, or B-F,
as described above.
For ADEMCO Contact ID
Format:
Enter any digit (other than "0") in the first box, to enable zone to
report. This is an "enabling" code only and is not the actual
report sent to the central office.
Entries in the second box will be ignored.
An entry of "0" in the first box for any report format
will disable a report. An entry of "0" in the second
box will result in automatic advance to the next field
when programming. To send "0" as a digit, you
must enter # + 10.
Examples:
For Code 3 (Single Digit), enter: 3 0
For Code 32 (Two Digits), enter: 3 2
For Code B2 (Hexadecimal) enter: #11 2
Vista de pagina 4
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios