ADEMCO 4110XM Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
- 4 -
Field Function Programmed Value [ ] = Default Value
*38 ENTRY DELAY
[2]
0 = 0 sec; 1 = 20 sec; 2 = 30 sec; 3 = 45 sec; 4 = 60 sec; 5 = 90 sec.
EXIT Delay = ENTRY Delay + 15 sec
*39 ZONE 3 RESPONSE TO OPEN
[0]
0 = 400 ms nominal; 1 = 10 ms nominal
DIALER PROGRAMMING (*40-*49)
For fields *40-*42, enter digits 0-9, or # + 11 for [6
66
6], # + 12 for [#], # + 13 for 2 second pause. If fewer than the
maximum number of digits is entered, exit the field by pressing [6
66
6] followed by the next field number to be programmed.
*40 PABX ACCESS CODE
Enter 4 digits. To clear entries from field, press *40*.
*41 PRIMARY PHONE No.
Enter up to 12 digits. Do not fill unused spaces.
To clear entries from field, press *41*.
*42 SECONDARY PHONE No.
Enter up to 12 digits. Do not fill unused spaces.
To clear entries from field, press *42*.
*43 SUBSCRIBER ACCOUNT No.
Enter 0-9; #+11 for B; #+12 for C;#+13 for D; #+14 for E; [#+15 for F].
Enter 6 as 4th digit, if 3+1 dialer reporting is to be used. If only 3 digits
used, exit by pressing 6 (and press 44, if entering next field). To clear
entries from field, press *43*.
Examples: For Acct No. 1234, enter: 1 2 3 4
For Acct No. B234, enter:
#+11
2 3 4
For Acct No. 123, enter: 1 2 3 *
*44 REPORT FORMAT [0]
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO
EXPRESS
7 = ADEMCO CONTACT ID
REPORTING
8 = 3+1, 4+1 ADEMCO L/S
EXPANDED
9 = 3+1, 4+1 RADIONICS
EXPANDED
*45 PHONE SYSTEM SELECT
[0]
If Cent. Sta. IS NOT on a WATS line: 0 = Pulse Dial; 1 = Tone Dial
If Cent. Sta. IS on a WATS line: 2 = Pulse Dial; 3 = Tone Dial
*46 SESCOA/RADIONICS SELECT
[0]
0 = Radionics (0-9, B-F reporting); 1 = SESCOA (0-9 only reporting)
*47 15 SEC DIALER DELAY (BURG)
[0]
0 = no, 1 = yes
*48 PERIODIC TEST MESSAGE
[0]
0 = none, 1 = 24 hrs; 2 = weekly (enter Test Code in field *64)
(Initial report is sent 12 hrs. after exiting programming or downloading.)
Entry of a number other than one specified will give unpredictable results.
Vista de pagina 3
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios