Electrical
• Primary power: 18VAC @ 72VA
ADEMCO No. 1451
• Control Panel quiescent
current draw: 300mA
• Backup battery:
– 12VDC, 12AH min to 34.4AH max
– Lead acid battery (gel type)
• Alarm power: 12VDC, 1.7A max for
each notification (bell) circuit output
Total 2.3A @ 12V
• Aux. standby pwr: 12VDC, 1A max
• Total power: 2.3A at 12VDC, 3.4A at
24VDC from all sources
• Standby time: 24 hours with 1A
standby load using 34.4AH battery
• Fusing: Battery input, aux. and
notification (bell) circuit outputs are
protected using PTC circuit protectors.
All outputs are power limited
• Optional 24-volt power supply, PS 24
supplies two 24 VFW, 1.7A full wave
rectified, unfiltered outputs
Main Dialer
• Line seize: Double Pole
• Ringer equiv.: 0.7B
• Formats: ADEMCO Low Speed,
ADEMCO 4+2 Express, ADEMCO High
Speed, ADEMCO Contact ID, Sescoa
and Radionics
• Dual phone line capability
(using 5140DLM module)
Cabinet Dimensions
• 18" H X 14.5" W X 4.3" D
Environmental
• Storage temp:
14° F to 158° F
(-10° C to 70° C)
• Operating temp:
32° F to 122° F
(0° C to 50° C)
• Humidity: 85% RH
• EMI: Meets or exceeds the
following requirements:
– FCC Part 15, Class B Device
– FCC Part 68
– IEC EMC Directive
Agency Listings
• UL609 Grade A Local Mercantile
Premises and Mercantile Safe
and Vault
• UL611/1610 Grades A, AA, Central
Station
• UL365 Grades A, AA Police Connect
• UL864/NFPA72 Local, Central Station
and Remote Station
• UL985
• Factory Mutual
• California State Fire Marshal
• MEA
• CAN/ULC S304 – Central and
Monitoring Station Burglar Alarm Unit
• CAN/ULC S527 – Central Unit for Fire
Alarm Systems
• CAN/ULC S303 – Local Burglar Alarm
Unit
• CAN/ULC S525 – Audible Signal
Appliances
SPECIFICATIONS