2
1234 567 89
J2 CONNECTOR
BLACK
GREY
YELLOW
RED
GREEN
BROWN
BLUE
VIOLET
4142TR CABLE (SUPPLIED WITH 4100SM)
4100SM
SERIAL
MODULE
+ PWR
- (GND)
RXD
NOT USED
NOT USED
TXD
NOT USED
DTR
BLUE WHITE
TO
AUTOMATION
EQUIPMENT
(RS232 INTERFACE)
RED
4100SM-015-V1
AUX PWR.
AUX GND.
11 12
CONTROL PANEL
WHITE
8
7
6
5
4
3
2
1
Figure 2: Wiring the 4100SM for Home/Facility Automation Control
Important Notes:
For information regarding Crestron equipment and software required for interfacing to the control
panel, contact Crestron at 1-888-CRESTRON (273-7876).
For information regarding AMX equipment and software required for interfacing to the control panel,
contact their support services.
The outputs of the ADEMCO VA8201 Module and the ADEMCO 4100SM are serial (RS232) outputs.
The distance between the ADEMCO VA8201 or the ADEMCO 4100SM and the Control Panel
cannot be further than the length of the 4142TR Trigger Cable.
The distance between the ADEMCO VA8201 or the ADEMCO 4100SM and the 3rd party
Home/Facility Automation hardware can be up to 50’. If shielded wire, wire in conduit, or Cat 5
unshielded is used, the maximum distance is 25’.
Programming the Control Panel for Home/Facility Automation Control
For detailed information concerning the control panel’s programming procedures, refer to the control panel’s
Programming Guide.
Programming for the ADEMCO VA8201
05 Enter 1 to view all zone faults/restores;
enter 0 to view only events enabled in field
179
14 Enter 1 for Home/Facility Automation
Control (cannot use both a serial printer
and Home/Facility Automation)
178 Extended Home Control Event Reports
(1=extended; 0=limited)
179 Home Control Event Report Types
(1=enable; 0=disable)
230 Enter 1 to enable the VA8201
319 Enter 1 for Home/Facility Automation
Control
NOTE: Fields 14, 230 and 319 MUST be set
for Home/Facility Automation Control.
Programming for the ADEMCO 4100SM
05 Enter 1 to view all zone faults/restores;
enter 0 to view only events enabled in field
170
14 Enter 1 for Home/Facility Automation
Control (cannot use both serial printer and
Home/Facility Automation)
178 Extended Home Control Event Reports
(1=extended; 0=limited)
179 Home Control Event Report Types
(1=enable; 0=disable)
230 Must be set with a 0
319 Enter 1 for Home/Facility Automation
Control
NOTE: Fields 14, and 319 MUST be set for
Home/Facility Automation Control.