PROMPT
ENTER ON KEYPAD
COMMENTS
-
4112 800
Enter Programming Mode (disarm state only)
PROGRAM KEYSWITCH
*56
Zone Programming Menu Mode.
Set to Confirm?
0=NO 1=YES
*
Get to Zone area.
Enter zn num
00=quit 01
01*
Zone number. In this case, Zone 1 is being used.
ZN ZT P RC HW:RT
01 00 1 00 EL:1
*
Enters ZONE TYPE.
ZN T
77*
Configure zone type for KEYSWITCH.
ZN ZT P RC HW:RT
01 77 1 00 EL:1
*00
Get out of zone programming.
PROGRAM OUTPUTS
Enter * or #
*80
Output Programming Menu mode.
OUTPUT FUNCT #
00=QUIT 0X
01*
Output function number XX (01-12).
01 A E P TRIG
?00 0 0 - ZN=00
*2
Activate output by zone type.
01 Enter Zn Type
Keysw xx
*78
Zone type = 78 (could be 78 or 79, 78= red LED, 79= green LED).
01 Partition
x
1*
Type in partition.
Enter output No.
Txx x
17*
Output number (17 or 18 are the choices)
TG1Express w/Ademco Vista 15P (Interactive Services Panel Programming)